Description
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
OR
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 8.0
*cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* versions up to (including) 7.2
*cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*
Changed
Reference Type
https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf No Types Assigned