Description

On SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, vSRX Series devices using tenant services on Juniper Networks Junos OS, due to incorrect permission scheme assigned to tenant system administrators, a tenant system administrator may inadvertently send their network traffic to one or more tenants while concurrently modifying the overall device system traffic management, affecting all tenants and the service provider. Further, a tenant may inadvertently receive traffic from another tenant. This issue affects: Juniper Networks Junos OS 18.3 version 18.3R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2; 18.4 version 18.4R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.1 versions 19.1R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.3 versions prior to 19.3R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.4 versions prior to 19.4R2-S4, 19.4R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 20.1 versions prior to 20.1R2, 20.1R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.2 versions prior to 20.2R2-S1, 20.2R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.3 versions prior to 20.3R1-S2, 20.3R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.4 versions prior to 20.4R1, 20.4R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series. This issue does not affect Juniper Networks Junos OS versions prior to 18.3R1.


Metrics

NVD enrichment efforts reference publicly available information to associate vector strings. CVSS information contributed by other sources is also displayed.
CVSS 4.0 Severity and Vector Strings:

NIST CVSS score
NIST: NVD
N/A
NVD assessment not yet provided.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://kb.juniper.net/JSA11130 Vendor Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-276 Incorrect Default Permissions cwe source acceptance level NIST   Juniper Networks, Inc.  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

2 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2021-0235
NVD Published Date:
04/22/2021
NVD Last Modified:
04/27/2021
Source:
Juniper Networks, Inc.