CVE-2024-39561 Detail

Description

An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX4600 and SRX5000 Series allows an attacker to send TCP packets with SYN/FIN or SYN/RST flags, bypassing the expected blocking of these packets. A TCP packet with SYN/FIN or SYN/RST should be dropped in flowd. However, when no-syn-check and Express Path are enabled, these TCP packets are unexpectedly transferred to the downstream network. This issue affects Junos OS on SRX4600 and SRX5000 Series: * All versions before 21.2R3-S8, * from 21.4 before 21.4R3-S7, * from 22.1 before 22.1R3-S6, * from 22.2 before 22.2R3-S4, * from 22.3 before 22.3R3-S3, * from 22.4 before 22.4R3-S2, * from 23.2 before 23.2R2, * from 23.4 before 23.4R1-S1, 23.4R2.


Metrics

NVD enrichment efforts reference publicly available information to associate vector strings. CVSS information contributed by other sources is also displayed.
CVSS 4.0 Severity and Vector Strings:

NIST CVSS score
NIST: NVD
N/A
NVD assessment not yet provided.

Nist CVSS score does not match with CNA score
CNA:  Juniper Networks, Inc.
CVSS-B 6.9 MEDIUM
Vector:  CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:N

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://supportportal.juniper.net/JSA83021
https://supportportal.juniper.net/JSA83021

Weakness Enumeration

CWE-ID CWE Name Source
CWE-754 Improper Check for Unusual or Exceptional Conditions Juniper Networks, Inc.  