Current Description

On Fitbit activity-tracker devices, certain addresses never change. According to the popets-2019-0036.pdf document, this leads to "permanent trackability" and "considerable privacy concerns" without a user-accessible anonymization feature. The devices, such as Charge 2, transmit Bluetooth Low Energy (BLE) advertising packets with a TxAdd flag indicating random addresses, but the addresses remain constant. If devices come within BLE range at one or more locations where an adversary has set up passive sniffing, the adversary can determine whether the same device has entered one of these locations.

Source:  MITRE
View Analysis Description

Impact

CVSS v3.0 Severity and Metrics:

Base Score: 6.5 MEDIUM
Vector: AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N (V3.0 legend)
Impact Score: 3.6
Exploitability Score: 2.8


Attack Vector (AV): Adjacent
Attack Complexity (AC): Low
Privileges Required (PR): None
User Interaction (UI): None
Scope (S): Unchanged
Confidentiality (C): High
Integrity (I): None
Availability (A): None

CVSS v2.0 Severity and Metrics:

Base Score: 3.3 LOW
Vector: (AV:A/AC:L/Au:N/C:P/I:N/A:N) (V2 legend)
Impact Subscore: 2.9
Exploitability Subscore: 6.5


Access Vector (AV): Local_Network
Access Complexity (AC): Low
Authentication (AU): None
Confidentiality (C): Partial
Integrity (I): None
Availability (A): None
Additional Information:
Allows unauthorized disclosure of information

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://petsymposium.org/2019/files/papers/issue3/popets-2019-0036.pdf Third Party Advisory
https://twitter.com/TedOnPrivacy/status/1151390589990187008 Third Party Advisory

Technical Details

Vulnerability Type (View All)

Known Affected Software Configurations Switch to CPE 2.2

Configuration 1 ( hide )
 cpe:2.3:o:fitbit:charge_2_firmware:-:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:fitbit:charge_2:-:*:*:*:*:*:*:*
     Show Matching CPE(s)


Change History

2 change records found - show changes

Quick Info

CVE Dictionary Entry:
CVE-2014-10374
NVD Published Date:
07/15/2019
NVD Last Modified:
07/24/2019