Current Description

The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.

Source:  MITRE
View Analysis Description

Impact

CVSS v2.0 Severity and Metrics:

Base Score: 6.8 MEDIUM
Vector: (AV:N/AC:M/Au:N/C:P/I:P/A:P) (V2 legend)
Impact Subscore: 6.4
Exploitability Subscore: 8.6


Access Vector (AV): Network
Access Complexity (AC): Medium
Authentication (AU): None
Confidentiality (C): Partial
Integrity (I): Partial
Availability (A): Partial
Additional Information:
Victim must voluntarily interact with attack mechanism
Allows unauthorized disclosure of information
Allows unauthorized modification
Allows disruption of service

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01 Vendor Advisory
http://www.zerodayinitiative.com/advisories/ZDI-15-626
http://www.zerodayinitiative.com/advisories/ZDI-15-627
http://www.zerodayinitiative.com/advisories/ZDI-15-628
http://www.zerodayinitiative.com/advisories/ZDI-15-629
https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02 Third Party Advisory US Government Resource

Technical Details

Vulnerability Type (View All)

  • Improper Restriction of Operations within the Bounds of a Memory Buffer (CWE-119)

Known Affected Software Configurations Switch to CPE 2.2

Configuration 1 ( hide )
 cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
Up to (including)
6.1