National Vulnerability Database

National Vulnerability Database

National Vulnerability
Database

CVE-2016-8374 Detail

Current Description

An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.

Source:  MITRE      Last Modified:  02/13/2017      View Analysis Description

Quick Info

CVE Dictionary Entry:
CVE-2016-8374
Original release date:
02/13/2017
Last revised:
03/16/2017
Source:
US-CERT/NIST

Impact

CVSS Severity (version 3.0):
CVSS v3 Base Score:
7.5 High
Vector:
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (legend)
Impact Score:
3.6
Exploitability Score:
3.9
CVSS Version 3 Metrics:
Attack Vector (AV):
Network
Attack Complexity (AC):
Low
Privileges Required (PR):
None
User Interaction (UI):
None
Scope (S):
Unchanged
Confidentiality (C):
None
Integrity (I):
None
Availability (A):
High
CVSS Severity (version 2.0):
CVSS v2 Base Score:
7.8 HIGH
Vector:
(AV:N/AC:L/Au:N/C:N/I:N/A:C) (legend)
Impact Subscore:
6.9
Exploitability Subscore:
10.0
CVSS Version 2 Metrics:
Access Vector:
Network exploitable
Access Complexity:
Low
Authentication:
Not required to exploit
Impact Type:
Allows disruption of service

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource Type Source Name
http://www.securityfocus.com/bid/94093 Third Party Advisory; VDB Entry External Source BID 94093
https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02 Third Party Advisory; US Government Resource External Source MISC https://ics-cert.us-cert.gov/advisories/ICSA-16-308-02

Technical Details

Vulnerability Type (View All)

  • Uncontrolled Resource Consumption ('Resource Exhaustion') (CWE-400)

Vulnerable software and versions Switch to CPE 2.2

Configuration 1
AND
OR
cpe:2.3:o:schneider_electric:magelis_gtu_universal_panel_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_gtu_universal_panel:-:*:*:*:*:*:*:*
Configuration 2
AND
OR
cpe:2.3:o:schneider_electric:magelis_gto_advanced_optimum_panel_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_gto_advanced_optimum_panel:-:*:*:*:*:*:*:*
Configuration 3
AND
OR
cpe:2.3:o:schneider_electric:magelis_sto5_small_panel_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_sto5_small__panel:-:*:*:*:*:*:*:*
Configuration 4
AND
OR
cpe:2.3:o:schneider_electric:magelis_stu_small_panel_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_stu_small__panel:-:*:*:*:*:*:*:*
Configuration 5
AND
OR
cpe:2.3:o:schneider_electric:magelis_xbt_gh_advanced_hand-held_panel_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_xbt_gh_advanced_hand-held_panel:-:*:*:*:*:*:*:*
Configuration 6
AND
OR
cpe:2.3:o:schneider_electric:magelis_xbt_gk_advanced_touchscreen_panel_with_keyboard_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_xbt_gk_advanced_touchscreen_panel_with_keyboard:-:*:*:*:*:*:*:*
Configuration 7
AND
OR
cpe:2.3:o:schneider_electric:magelis_xbt_gt_advanced_touchscreen_panel_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_xbt_gt_advanced_touchscreen_panel:-:*:*:*:*:*:*:*
Configuration 8
AND
OR
cpe:2.3:o:schneider_electric:magelis_xbt_gtw_advanced_open_touchscreen_panel_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:schneider_electric:magelis_xbt_gtw_advanced_open_touchscreen_panel:-:*:*:*:*:*:*:*

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History 2 change records found - show changes