Current Description

It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.

Source:  MITRE
View Analysis Description

Impact

CVSS v3.0 Severity and Metrics:

Base Score: 5.9 MEDIUM
Vector: AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N (V3 legend)
Impact Score: 3.6
Exploitability Score: 2.2


Attack Vector (AV): Network
Attack Complexity (AC): High
Privileges Required (PR): None
User Interaction (UI): None
Scope (S): Unchanged
Confidentiality (C): High
Integrity (I): None
Availability (A): None

CVSS v2.0 Severity and Metrics:

Base Score: 4.3 MEDIUM
Vector: (AV:N/AC:M/Au:N/C:P/I:N/A:N) (V2 legend)
Impact Subscore: 2.9
Exploitability Subscore: 8.6


Access Vector (AV): Network
Access Complexity (AC): Medium
Authentication (AU): None
Confidentiality (C): Partial
Integrity (I): None
Availability (A): None
Additional Information:
Allows unauthorized disclosure of information

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html Third Party Advisory VDB Entry
https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf Exploit Third Party Advisory
https://seclists.org/bugtraq/2019/Jun/8 Mailing List Third Party Advisory

Technical Details

Vulnerability Type (View All)

Known Affected Software Configurations Switch to CPE 2.2

Configuration 1 ( hide )
 cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
Up to (including)
bp700_10.1
Running on/with
 cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:*
     Show Matching CPE(s)