National Vulnerability Database

National Vulnerability Database

National Vulnerability
Database

CVE-2017-6780 Detail

Current Description

A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.

Source:  MITRE
Description Last Modified:  09/07/2017
View Analysis Description

Impact

CVSS v3.0 Severity and Metrics:

Base Score: 7.5 HIGH
Vector: AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (V3 legend)
Impact Score: 3.6
Exploitability Score: 3.9


Attack Vector (AV): Network
Attack Complexity (AC): Low
Privileges Required (PR): None
User Interaction (UI): None
Scope (S): Unchanged
Confidentiality (C): None
Integrity (I): None
Availability (A): High

CVSS v2.0 Severity and Metrics:

Base Score: 7.8 HIGH
Vector: (AV:N/AC:L/Au:N/C:N/I:N/A:C) (V2 legend)
Impact Subscore: 6.9
Exploitability Subscore: 10.0


Access Vector (AV): Network
Access Complexity (AC): Low
Authentication (AU): None
Confidentiality (C): None
Integrity (I): None
Availability (A): Complete
Additional Information:
Allows disruption of service

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
http://www.securityfocus.com/bid/100641 Third Party Advisory VDB Entry
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd Vendor Advisory

Technical Details

Vulnerability Type (View All)

  • Resource Management Errors (CWE-399)

Change History

2 change records found - show changes

Quick Info

CVE Dictionary Entry:
CVE-2017-6780
NVD Published Date:
09/07/2017
NVD Last Modified:
09/18/2017