National Vulnerability Database

National Vulnerability Database

National Vulnerability
Database

CVE-2018-0365 Detail

Current Description

A vulnerability in the web-based management interface of Cisco Firepower Management Center could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack and perform arbitrary actions on an affected device. The vulnerability is due to insufficient CSRF protections for the web-based management interface of the affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions on the targeted device via a web browser and with the privileges of the user. Cisco Bug IDs: CSCvb19750.

Source:  MITRE
View Analysis Description

Impact

CVSS v3.0 Severity and Metrics:

Base Score: 8.8 HIGH
Vector: AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H (V3 legend)
Impact Score: 5.9
Exploitability Score: 2.8


Attack Vector (AV): Network
Attack Complexity (AC): Low
Privileges Required (PR): None
User Interaction (UI): Required
Scope (S): Unchanged
Confidentiality (C): High
Integrity (I): High
Availability (A): High

CVSS v2.0 Severity and Metrics:

Base Score: 6.8 MEDIUM
Vector: (AV:N/AC:M/Au:N/C:P/I:P/A:P) (V2 legend)
Impact Subscore: 6.4
Exploitability Subscore: 8.6


Access Vector (AV): Network
Access Complexity (AC): Medium
Authentication (AU): None
Confidentiality (C): Partial
Integrity (I): Partial
Availability (A): Partial
Additional Information:
Victim must voluntarily interact with attack mechanism
Allows unauthorized disclosure of information
Allows unauthorized modification
Allows disruption of service

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
http://www.securityfocus.com/bid/104519 Third Party Advisory VDB Entry
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-firepower-csrf Vendor Advisory

Technical Details

Vulnerability Type (View All)

  • Cross-Site Request Forgery (CSRF) (CWE-352)

Known Affected Software Configurations Switch to CPE 2.2

Configuration 1 ( hide )
 cpe:2.3:a:cisco:firepower_management_center:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:firepower_management_center:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:firepower_management_center:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:firepower_management_center:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:firepower_management_center:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:firepower_management_center:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 2 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8360_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8360_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8360_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8360_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8360_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8360_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8360:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 3 ( hide )
 cpe:2.3:h:cisco:firepower_management_center_2500_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:h:cisco:firepower_management_center_2500_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:h:cisco:firepower_management_center_2500_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:h:cisco:firepower_management_center_2500_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:h:cisco:firepower_management_center_2500_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:h:cisco:firepower_management_center_2500_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_management_center_2500:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 4 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8120_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8120_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8120_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8120_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8120_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8120_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8120:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 5 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8260_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8260_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8260_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8260_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8260_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8260_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8260:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 6 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_7050_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_7050_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_7050_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_7050_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_7050_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_7050_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_7050:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 7 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8130_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8130_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8130_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8130_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8130_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8130_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8130:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 8 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8140_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8140_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8140_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8140_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8140_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8140_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8140:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 9 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8350_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8350_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8350_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8350_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8350_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8350_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8350:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 10 ( hide )
 cpe:2.3:o:cisco:amp_8150_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_8150_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_8150_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_8150_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_8150_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_8150_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:amp_8150:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 11 ( hide )
 cpe:2.3:o:cisco:amp_7150_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_7150_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_7150_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_7150_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_7150_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:amp_7150_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:amp_7150:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 12 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8270_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8270_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8270_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8270_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8270_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8270_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8270:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 13 ( hide )
 cpe:2.3:a:cisco:ngips_virtual_appliance:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:ngips_virtual_appliance:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:ngips_virtual_appliance:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:ngips_virtual_appliance:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:ngips_virtual_appliance:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:a:cisco:ngips_virtual_appliance:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 14 ( hide )
 cpe:2.3:o:cisco:firepower_appliance_8390_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8390_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8390_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8390_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8390_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_appliance_8390_firmware:6.2.3:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:cisco:firepower_appliance_8390:*:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 15 ( hide )
 cpe:2.3:o:cisco:firepower_management_center_4500_firmware:6.0.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_management_center_4500_firmware:6.1.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_management_center_4500_firmware:6.2.0:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_management_center_4500_firmware:6.2.1:*:*:*:*:*:*:*
     Show Matching CPE(s)
 cpe:2.3:o:cisco:firepower_management_center_4500_firmware:6.2.2:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with

Configuration 16 ( hide )

Configuration 17 ( hide )

Configuration 18 ( hide )

Configuration 19 ( hide )

Configuration 20 ( hide )

Configuration 21 ( hide )

Configuration 22 ( hide )

Configuration 23 ( hide )

Configuration 24 ( hide )

Configuration 25 ( hide )

Configuration 26 ( hide )

Configuration 27 ( hide )

Configuration 28 ( hide )

Configuration 29 ( hide )

Configuration 30 ( hide )

Configuration 31 ( hide )

Configuration 32 ( hide )

Showing 100 of 221 CPEs, view all CPEs here.

Change History

2 change records found - show changes

Quick Info

CVE Dictionary Entry:
CVE-2018-0365
NVD Published Date:
06/21/2018
NVD Last Modified:
08/21/2018