National Vulnerability Database

National Vulnerability Database

National Vulnerability
Database

CVE-2018-2568 Detail

Current Description

Vulnerability in the Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: Remote Console Application). Supported versions that are affected are 3.x and 4.x. Easily exploitable vulnerability allows unauthenticated attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized read access to a subset of Integrated Lights Out Manager (ILOM) accessible data and unauthorized ability to cause a partial denial of service (partial DOS) of Integrated Lights Out Manager (ILOM). CVSS 3.0 Base Score 7.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).

Source:  MITRE
Description Last Modified:  01/17/2018
View Analysis Description

Impact

CVSS v3.0 Severity and Metrics:

Base Score: 7.3 HIGH
Vector: AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L (V3 legend)
Impact Score: 3.4
Exploitability Score: 3.9


Attack Vector (AV): Network
Attack Complexity (AC): Low
Privileges Required (PR): None
User Interaction (UI): None
Scope (S): Unchanged
Confidentiality (C): Low
Integrity (I): Low
Availability (A): Low

CVSS v2.0 Severity and Metrics:

Base Score: 7.5 HIGH
Vector: (AV:N/AC:L/Au:N/C:P/I:P/A:P) (V2 legend)
Impact Subscore: 6.4
Exploitability Subscore: 10.0


Access Vector (AV): Network
Access Complexity (AC): Low
Authentication (AU): None
Confidentiality (C): Partial
Integrity (I): Partial
Availability (A): Partial
Additional Information:
Allows unauthorized disclosure of information
Allows unauthorized modification
Allows disruption of service

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html Patch Vendor Advisory
http://www.securityfocus.com/bid/102606 Third Party Advisory VDB Entry
http://www.securitytracker.com/id/1040205 Third Party Advisory VDB Entry

Technical Details

Vulnerability Type (View All)

  • Improper Access Control (CWE-284)

Vulnerable software and versions Switch to CPE 2.2

Configuration 1
OR
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.0:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.3:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.4:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.6:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.8:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.9:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.10:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.12:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.14:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.0.16:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.0:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.1:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.1.2:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.0:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.1:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.2:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.4:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.5:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.6:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.7:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.8:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:3.2.9:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:4.0.0:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:4.0.1:*:*:*:*:*:*:*
cpe:2.3:o:oracle:integrated_lights_out_manager_firmware:4.0.2:*:*:*:*:*:*:*

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

2 change records found - show changes

Quick Info

CVE Dictionary Entry:
CVE-2018-2568
NVD Published Date:
01/17/2018
NVD Last Modified:
02/14/2018