For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the Content Explorer application grants users the ability to upload files to shares and this image was rendered in the browser in the device's origin instead of prompting to download the asset. The application does not prevent the user from uploading SVG images and returns these images within their origin. As a result, malicious users can upload SVG images that contain arbitrary JavaScript that is evaluated when the victim issues a request to download the file.

Source:  MITRE
View Analysis Description

Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score: 8.8 HIGH
Vector:  CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://support.lenovo.com/us/en/solutions/LEN-24224 Vendor Advisory

Weakness Enumeration

CWE-ID CWE Name Source
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') NIST  

Known Affected Software Configurations Switch to CPE 2.2

Configuration 1 ( hide )
 cpe:2.3:o:lenovo:storcenter_px12-450r_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_px12-450r:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 2 ( hide )
 cpe:2.3:o:lenovo:storcenter_px12-400r_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_px12-400r:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 3 ( hide )
 cpe:2.3:o:lenovo:storcenter_px4-300r_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_px4-300r:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 4 ( hide )
 cpe:2.3:o:lenovo:storcenter_px6-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_px6-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 5 ( hide )
 cpe:2.3:o:lenovo:storcenter_px4-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_px4-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 6 ( hide )
 cpe:2.3:o:lenovo:storcenter_px2-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_px2-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 7 ( hide )
 cpe:2.3:o:lenovo:storcenter_ix4-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_ix4-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 8 ( hide )
 cpe:2.3:o:lenovo:storcenter_ix2_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_ix2:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 9 ( hide )
 cpe:2.3:o:lenovo:storcenter_ix2-dl_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:storcenter_ix2-dl:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 10 ( hide )
 cpe:2.3:o:lenovo:ez_media_\&_backup_center_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:ez_media_\&_backup_center:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 11 ( hide )
 cpe:2.3:o:lenovo:px12-450r_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px12-450r:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 12 ( hide )
 cpe:2.3:o:lenovo:px12-400r_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px12-400r:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 13 ( hide )
 cpe:2.3:o:lenovo:px4-400r_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px4-400r:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 14 ( hide )
 cpe:2.3:o:lenovo:px4-300r_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px4-300r:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 15 ( hide )
 cpe:2.3:o:lenovo:px6-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px6-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 16 ( hide )
 cpe:2.3:o:lenovo:px4-400d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px4-400d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 17 ( hide )
 cpe:2.3:o:lenovo:px4-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px4-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 18 ( hide )
 cpe:2.3:o:lenovo:px2-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:px2-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 19 ( hide )
 cpe:2.3:o:lenovo:ix4-300d_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:ix4-300d:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 20 ( hide )
 cpe:2.3:o:lenovo:ix2_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:ix2:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 21 ( hide )
 cpe:2.3:o:lenovo:ez_media_\&_backup_center_firmware:4.1.402.34662:*:*:*:*:*:*:*
     Show Matching CPE(s)
Running on/with
 cpe:2.3:h:lenovo:ez_media_\&_backup_center:-:*:*:*:*:*:*:*
     Show Matching CPE(s)


Change History

2 change records found - show changes

Quick Info

CVE Dictionary Entry:
CVE-2018-9078
NVD Published Date:
09/28/2018
NVD Last Modified:
10/02/2019