Description

On EX4600, QFX5100 Series, NFX Series, QFX10K Series, QFX5110, QFX5200 Series, QFX5110, QFX5200, QFX10K Series, vSRX, SRX1500, SRX4000 Series, vSRX, SRX1500, SRX4000, QFX5110, QFX5200, QFX10K Series, when the user uses console management port to authenticate, the credentials used during device authentication are written to a log file in clear text. This issue does not affect users that are logging-in using telnet, SSH or J-web to the management IP. This issue affects ACX, NFX, SRX, EX and QFX platforms with the Linux Host OS architecture, it does not affect other SRX and EX platforms that do not use the Linux Host OS architecture. This issue affects Juniper Networks Junos OS: 15.1X49 versions prior to 15.1X49-D110 on vSRX, SRX1500, SRX4000 Series; 15.1X53 versions prior to 15.1X53-D234 on QFX5110, QFX5200 Series; 15.1X53 versions prior to 15.1X53-D68 on QFX10K Series; 17.1 versions prior to 17.1R2-S8, 17.1R3, on QFX5110, QFX5200, QFX10K Series; 17.2 versions prior to 17.2R1-S7, 17.2R2-S6, 17.2R3 on QFX5110, QFX5200, QFX10K Series; 17.3 versions prior to 17.3R2 on vSRX, SRX1500, SRX4000, QFX5110, QFX5200, QFX10K Series; 14.1X53 versions prior to 14.1X53-D47 on ACX5000, EX4600, QFX5100 Series; 15.1 versions prior to 15.1R7 on ACX5000, EX4600, QFX5100 Series; 16.1R7 versions prior to 16.1R7 on ACX5000, EX4600, QFX5100 Series; 17.1 versions prior to 17.1R2-S10, 17.1R3 on ACX5000, EX4600, QFX5100 Series; 17.2 versions prior to 17.2R3 on ACX5000, EX4600, QFX5100 Series; 17.3 versions prior to 17.3R3 on ACX5000, EX4600, QFX5100 Series; 17.4 versions prior to 17.4R2 on ACX5000, EX4600, QFX5100 Series; 18.1 versions prior to 18.1R2 on ACX5000, EX4600, QFX5100 Series; 15.1X53 versions prior to 15.1X53-D496 on NFX Series, 17.2 versions prior to 17.2R3-S1 on NFX Series; 17.3 versions prior to 17.3R3-S4 on NFX Series; 17.4 versions prior to 17.4R2-S4, 17.4R3 on NFX Series, 18.1 versions prior to 18.1R3-S4 on NFX Series; 18.2 versions prior to 18.2R2-S3, 18.2R3 on NFX Series; 18.3 versions prior to 18.3R1-S3, 18.3R2 on NFX Series; 18.4 versions prior to 18.4R1-S1, 18.4R2 on NFX Series.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  5.5 MEDIUM
Vector:  CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Nist CVSS score does not match with CNA score
CNA:  Juniper Networks, Inc.
Base Score:  5.9 MEDIUM
Vector:  CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://kb.juniper.net/JSA10969 Vendor Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-319 Cleartext Transmission of Sensitive Information cwe source acceptance level NIST  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

6 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2019-0069
NVD Published Date:
10/09/2019
NVD Last Modified:
02/05/2021
Source:
Juniper Networks, Inc.