Current Description

A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.

Source:  MITRE
View Analysis Description

Impact

CVSS v3.0 Severity and Metrics:

Base Score: 6.6 MEDIUM
Vector: AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (V3 legend)
Impact Score: 5.9
Exploitability Score: 0.7


Attack Vector (AV): Physical
Attack Complexity (AC): Low
Privileges Required (PR): Low
User Interaction (UI): None
Scope (S): Unchanged
Confidentiality (C): High
Integrity (I): High
Availability (A): High

CVSS v2.0 Severity and Metrics:

Base Score: 4.6 MEDIUM
Vector: (AV:L/AC:L/Au:N/C:P/I:P/A:P) (V2 legend)
Impact Subscore: 6.4
Exploitability Subscore: 3.9


Access Vector (AV): Local
Access Complexity (AC): Low
Authentication (AU): None
Confidentiality (C): Partial
Integrity (I): Partial
Availability (A): Partial
Additional Information:
Allows unauthorized disclosure of information
Allows unauthorized modification
Allows disruption of service

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf Vendor Advisory

Technical Details

Vulnerability Type (View All)

  • Improper Neutralization of Special Elements used in a Command ('Command Injection') (CWE-77)

Known Affected Software Configurations Switch to CPE 2.2

Configuration 1 ( hide )
 cpe:2.3:o:siemens:scalance_sc-600_firmware:2.0:*:*:*:*:*:*:*