Description
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient monitoring.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
Title: dispositivos de monitorización SC de Dräger, Description: Los dispositivos de monitorización Dräger SC (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contienen credenciales de texto plano codificadas de forma rígida en el código fuente y una vulnerabilidad de denegación de servicio que permite a atacantes locales y remotos comprometer la integridad del dispositivo en todas las versiones de software. Un atacante local con acceso directo al dispositivo puede usar las credenciales codificadas de forma rígida para acceder a cuentas de servicio y clínicas y alterar la configuración del dispositivo, mientras que un atacante remoto puede enviar paquetes de red malformados para causar reinicios repetidos del dispositivo, lo que finalmente resulta en la pérdida de conectividad de red y la interrupción de la monitorización del paciente.
New CVE Received from VulnCheck6/02/2026 4:16:23 PM
Action
Type
Old Value
New Value
Added
Description
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient monitoring.