CVE-2019-6568 Detail

Current Description

A vulnerability has been identified in CP1604, CP1616, CP343-1 Advanced (incl. SIPLUS NET variants), CP443-1 (incl. SIPLUS NET variants), CP443-1 Advanced (incl. SIPLUS NET variants), CP443-1 OPC UA (incl. SIPLUS NET variants), RFID 181EIP, SIMATIC CP 1616 and CP 1604, SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variants), SIMATIC CP 443-1 (incl. SIPLUS NET variants), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variants), SIMATIC CP 443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200 SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (incl. SIPLUS variants), SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600 family, SIMATIC RF600R, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5.1 SP1 Control Unit, SINAMICS G150 V4.6 Control Unit, SINAMICS G150 V4.7 Control Unit, SINAMICS G150 V4.7 SP1 Control Unit, SINAMICS G150 V4.8 Control Unit, SINAMICS G150 V5.1 Control Unit, SINAMICS G150 V5.1 SP1 Control Unit, SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants), SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants), SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants), SINAMICS S150 V4.6 Control Unit, SINAMICS S150 V4.7 Control Unit, SINAMICS S150 V4.7 SP1 Control Unit, SINAMICS S150 V4.8 Control Unit, SINAMICS S150 V5.1 Control Unit, SINAMICS S150 V5.1 SP1 Control Unit, SINAMICS S210 V5.1 Control Unit, SINAMICS S210 V5.1 SP1 Control Unit, SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. SIPLUS variants), TIM 1531 IRC (incl. SIPLUS NET variants), TIM 1531 IRC (incl. SIPLUS variants). The webserver of the affected devices contains a vulnerability that may lead to a denial-of-service condition. An attacker may cause a denial-of-service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.


View Analysis Description

Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  7.5 HIGH
Vector:  CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf Vendor Advisory 
https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf

Weakness Enumeration

CWE-ID CWE Name Source
CWE-20 Improper Input Validation cwe source acceptance level NIST  
CWE-125 Out-of-bounds Read Reference acceptance level Siemens AG  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

12 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2019-6568
NVD Published Date:
04/17/2019
NVD Last Modified:
02/11/2020
Source:
MITRE