Current Description
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
AND
OR
*cpe:2.3:o:philips:intellivue_mp2-mp90_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mp2-mp90:n:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx100:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx400:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx550:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx600_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx600:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx700:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx750_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx750:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx800:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx850_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx850:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_x2:n:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_x3:n:*:*:*:*:*:*:*
Added
CPE Configuration
OR
*cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:*
*cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*
*cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*
*cpe:2.3:a:philips:performancebridge_focal_point:a.01:*:*:*:*:*:*:*
Added
CVSS V2
NIST (AV:A/AC:L/Au:N/C:N/I:N/A:C)
Added
CVSS V3.1
NIST AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Changed
Reference Type
https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 No Types Assigned
https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 Third Party Advisory, US Government Resource
Quick Info
CVE Dictionary Entry: CVE-2020-16216 NVD
Published Date: 09/11/2020 NVD
Last Modified: 12/12/2023
Source: ICS-CERT