Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
OR
*cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:* versions up to (excluding) 11.3
*cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:* versions up to (excluding) 2.6
*cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:* versions up to (excluding) 8.0
*cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*
*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:* versions up to (excluding) 3.0
*cpe:2.3:a:siemens:simatic_pcs_neo:3.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* versions from (including) 15 up to (excluding) 15.1
*cpe:2.3:a:siemens:simatic_step_7:15.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* versions up to (excluding) 15.1
*cpe:2.3:a:siemens:simocode_es:15.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* versions up to (excluding) 15.1
*cpe:2.3:a:siemens:soft_starter_es:15.1:-:*:*:*:*:*:*
OR
*cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:* versions up to (excluding) 3.3
*cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:* versions up to (excluding) 11.3
*cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:* versions up to (excluding) 2.6
*cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:* versions up to (excluding) 8.0
*cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*
*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:* versions up to (excluding) 3.0
*cpe:2.3:a:siemens:simatic_pcs_neo:3.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* versions from (including) 15 up to (excluding) 15.1
*cpe:2.3:a:siemens:simatic_step_7:15.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* versions up to (excluding) 15.1
*cpe:2.3:a:siemens:simocode_es:15.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* versions up to (excluding) 15.1
*cpe:2.3:a:siemens:soft_starter_es:15.1:-:*:*:*:*:*:*
CVE Modified by Siemens AG8/10/2022 4:15:18 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote denial-of-service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG8/10/2022 8:15:10 AM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote denial-of-service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
Modified Analysis by NIST10/18/2021 8:36:14 AM
Action
Type
Old Value
New Value
Changed
CPE Configuration
OR
*cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:* versions up to (excluding) 11.3
*cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*
*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* versions from (including) 15 up to (including) 15.1
*cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*
OR
*cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:* versions up to (excluding) 11.3
*cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:* versions up to (excluding) 2.6
*cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:* versions up to (excluding) 8.0
*cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*
*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:* versions up to (excluding) 3.0
*cpe:2.3:a:siemens:simatic_pcs_neo:3.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* versions from (including) 15 up to (excluding) 15.1
*cpe:2.3:a:siemens:simatic_step_7:15.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* versions up to (excluding) 15.1
*cpe:2.3:a:siemens:simocode_es:15.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* versions up to (excluding) 15.1
*cpe:2.3:a:siemens:soft_starter_es:15.1:-:*:*:*:*:*:*
CVE Modified by Siemens AG7/13/2021 8:15:09 AM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote Denial-of-Service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG7/13/2021 7:15:09 AM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote Denial-of-Service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
CVE Modified by Siemens AG4/22/2021 5:15:09 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG3/15/2021 2:15:17 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote Denial-of-Service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG3/15/2021 1:15:21 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote Denial-of-Service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
CVE Modified by Siemens AG2/09/2021 1:15:50 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), Soft Starter ES (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), SIMOCODE ES <= V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES (All versions < V16 Update 1), Soft Starter ES <= V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG12/14/2020 5:15:16 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), Soft Starter ES (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote Denial-of-Service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), Soft Starter ES (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG12/14/2020 4:15:21 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), Soft Starter ES (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could
cause a partial remote Denial-of-Service, that would cause the service
to restart itself.
On some cases the vulnerability could leak random information from the
remote service.
CVE Modified by Siemens AG11/12/2020 3:15:28 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions < V16 Update 1), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG9/09/2020 3:15:22 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
CVE Modified by Siemens AG8/14/2020 12:15:17 PM
Action
Type
Old Value
New Value
Changed
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
Initial Analysis by NIST7/20/2020 12:00:36 PM
Action
Type
Old Value
New Value
Added
CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L
Added
CVSS V2
NIST (AV:N/AC:L/Au:N/C:P/I:N/A:P)
Added
CWE
NIST CWE-400
Added
CPE Configuration
OR
*cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:* versions up to (excluding) 3.2
*cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:* versions up to (excluding) 11.3
*cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*
*cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* versions from (including) 15 up to (including) 15.1
*cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*
Changed
Reference Type
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf No Types Assigned