CVE-2020-8144 DetailDescriptionThe UniFi Video Server v3.9.3 and prior (for Windows 7/8/10 x64) web interface Firmware Update functionality, under certain circumstances, does not validate firmware download destinations to ensure they are within the intended destination directory tree. It accepts a request with a URL to firmware update information. If the version field contains ..\ character sequences, the destination file path to save the firmware can be manipulated to be outside the intended destination directory tree. Fixed in UniFi Video Controller v3.10.3 and newer. Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
CVSS 4.0 Severity and Vector Strings:
References to Advisories, Solutions, and ToolsBy selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.
Weakness Enumeration
Known Affected Software Configurations Switch to CPE 2.2CPEs loading, please wait.
Denotes Vulnerable Software Quick InfoCVE Dictionary Entry:CVE-2020-8144 NVD Published Date: 04/01/2020 NVD Last Modified: 04/03/2020 Source: HackerOne |