This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided.
Description
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:p2_ethernet:*:*:* versions up to (excluding) 2.8.19
*cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:bacnet:*:*:* versions up to (excluding) 3.5.4
OR
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:p2_ethernet:*:*:* versions up to (excluding) 2.8.19
*cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:bacnet:*:*:* versions up to (excluding) 3.5.4
OR
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.5.4
OR
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.5.4
OR
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*
Changed
CPE Configuration
OR
*cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2013.08.1
*cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*
OR
*cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2017.02.4
*cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc00-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc00-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc00-u_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc00-u:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc001-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc001-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc100-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc100-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc12-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc12-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc128-u_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc128-u:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc200-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc200-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc22-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc22-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc22.1-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc22.1-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc36.1-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc36.1-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc50-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc50-e.d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxc64-u_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxc64-u:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:desigo_pxm20-e_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016
OR
cpe:2.3:h:siemens:desigo_pxm20-e:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*
Added
CPE Configuration
OR
*cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2013.08.1
*cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*
Changed
Reference Type
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf No Types Assigned