Current Description
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Capital VSTAR (All versions), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options),
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
Added
Reference
Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-044112.html [No types assigned]
Added
Reference
Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-114589.html [No types assigned]
Added
Reference
Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-223353.html [No types assigned]
Added
Reference
Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-620288.html [No types assigned]
Added
Reference
Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-845392.html [No types assigned]
AND
OR
*cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*
Added
CPE Configuration
OR
*cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2017.02.3
*cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*
Added
CVSS V2
NIST (AV:N/AC:L/Au:N/C:P/I:N/A:P)
Added
CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
Changed
Reference Type
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf No Types Assigned