You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided.
Description
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
OR
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 8.2
*cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* versions up to (including) 7.4
*cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_win
OR
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 8.2
*cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* versions up to (excluding) 7.4
*cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_win
OR
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 8.2
*cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* versions up to (including) 7.4
*cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_win
Changed
Reference Type
https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf No Types Assigned