Description
An Improper Preservation of Consistency Between Independent Representations of Shared State vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS) to device due to out of resources. When a device is configured with "service-provider/SP style" switching, and mac-limiting is configured on an Aggregated Ethernet (ae) interface, and then a PFE is restarted or the device is rebooted, mac-limiting doesn't work anymore. Please note that the issue might not be apparent as traffic will continue to flow through the device although the mac table and respective logs will indicate that mac limit is reached. Functionality can be restored by removing and re-adding the MAC limit configuration. This issue affects Juniper Networks Junos OS on QFX5k Series, EX46xx Series: All versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3 on; 21.4 versions prior to 21.4R3 on; 22.1 versions prior to 22.1R2 on.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].