Description
A blind SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in the alerts_count component, allows an authenticated attacker to execute arbitrary SQL statements on the DBMS used by the web application.
Authenticated users may be able to extract arbitrary information from the DBMS in an uncontrolled way, alter its structure and data, and/or affect its availability.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
CVE Modified by Nozomi Networks Inc.9/20/2024 8:15:03 AM
Action
Type
Old Value
New Value
Changed
Description
A blind SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in the alerts_count component, allows an authenticated attacker to execute arbitrary SQL queries on the DBMS used by the web application.
Authenticated users can extract arbitrary information from the DBMS in an uncontrolled way.
A blind SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in the alerts_count component, allows an authenticated attacker to execute arbitrary SQL statements on the DBMS used by the web application.
Authenticated users may be able to extract arbitrary information from the DBMS in an uncontrolled way, alter its structure and data, and/or affect its availability.
Added
CVSS V4.0
Nozomi Networks Inc. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Removed
CVSS V4.0
Nozomi Networks Inc. AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Added
CVSS V3.1
Nozomi Networks Inc. AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Removed
CVSS V3.1
Nozomi Networks Inc. AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L
CVE Modified by Nozomi Networks Inc.5/28/2024 9:15:09 AM
Action
Type
Old Value
New Value
Changed
Description
A blind SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in the alerts_count component, allows an authenticated attacker to execute arbitrary SQL queries on the DBMS used by the web application.
Authenticated users can extract arbitrary information from the DBMS in an uncontrolled way.
A blind SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in the alerts_count component, allows an authenticated attacker to execute arbitrary SQL queries on the DBMS used by the web application.
Authenticated users can extract arbitrary information from the DBMS in an uncontrolled way.
Added
CVSS V4.0
Nozomi Networks Inc. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVE Modified by Nozomi Networks Inc.5/14/2024 8:24:06 AM
Action
Type
Old Value
New Value
Reanalysis by NIST8/15/2023 12:07:24 PM
Action
Type
Old Value
New Value
Added
CVSS V3.1
NIST AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Removed
CVSS V3.1
NIST AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Initial Analysis by NIST8/15/2023 12:03:32 PM
Action
Type
Old Value
New Value
Added
CVSS V3.1
NIST AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Added
CWE
NIST CWE-89
Added
CPE Configuration
OR
*cpe:2.3:a:nozominetworks:cmc:*:*:*:*:*:*:*:* versions up to (excluding) 22.6.2
*cpe:2.3:a:nozominetworks:guardian:*:*:*:*:*:*:*:* versions up to (excluding) 22.6.2
Changed
Reference Type
https://security.nozominetworks.com/NN-2023:3-01 No Types Assigned