Current Description

Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. Changes still cannot be made outside of the established therapy parameters of the programmer. For unauthorized access to occur, an individual would need physical access to the Smart Programmer.


View Analysis Description

Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  6.8 MEDIUM
Vector:  CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Nist CVSS score does not match with CNA score
CNA:  Medtronic
Base Score:  6.4 MEDIUM
Vector:  CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://global.medtronic.com/xg-en/product-security/security-bulletins/pelvic-health-interstim-micro.html Vendor Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-287 Improper Authentication cwe source acceptance level NIST  
CWE-620 Unverified Password Change Reference acceptance level Medtronic  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

2 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2023-25931
NVD Published Date:
03/01/2023
NVD Last Modified:
11/06/2023
Source: