You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided.
Description
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
Siemens AG CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Added
Reference
Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-407785.html [No types assigned]
OR
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 34.1 up to (excluding) 34.1.258
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 35.0 up to (excluding) 35.0.254
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 35.1 up to (excluding) 35.1.171
*cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* versions from (including) 14.2 up to (ex
OR
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 34.1 up to (excluding) 34.1.258
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 35.0 up to (excluding) 35.0.254
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 35.1 up to (excluding) 35.1.171
*cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* versions from (including) 14.1 up to (excluding) 14.1.0.11
*cpe:2.3:a:siemens:teamcenter_visualization:
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execut
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could al
OR
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 34.1 up to (excluding) 34.1.258
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 35.0 up to (excluding) 35.0.254
*cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* versions from (including) 35.1 up to (excluding) 35.1.171
*cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* versions from (including) 14.2 up to (ex
Changed
Reference Type