A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below.
Incomplete or wrong received APDU frame layout may
cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer
with wrong length information of APDU or delayed reception
of data octets.
Only communication link of affected HCI IEC 60870-5-104
is blocked. If attack sequence stops the communication to
the previously attacked link gets normal again.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
AND
OR
*cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:* versions from (including) 12.0.1 up to (including) 12.0.14
*cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:* versions from (including) 12.2.1 up to (including) 12.2.11
*cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:* versions from (including) 12.4.1 up to (including) 12.4.11
*cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:* versions from (including) 12.6.1 up to (inc
AND
OR
*cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:* versions from (including) 12.0.1 up to (including) 12.0.14
*cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:* versions from (including) 12.2.1 up to (including) 12.2.11
*cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:* versions from (including) 12.4.1 up to (including) 12.4.11
*cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:* versions from (including) 12.6.1 up to (inc
AND
OR
*cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:* versions from (including) 12.0.1 up to (including) 12.0.14
*cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:* versions from (including) 12.2.1 up to (including) 12.2.11
*cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:* versions from (including) 12.4.1 up to (including) 12.4.11
*cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:* versions from (including) 12.6.1 up to (inc
AND
OR
*cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:* versions from (including) 12.0.1 up to (including) 12.0.14
*cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:* versions from (including) 12.2.1 up to (including) 12.2.11
*cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:* versions from (including) 12.4.1 up to (including) 12.4.11
*cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:* versions from (including) 12.6.1 up to (inc
Added
CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Added
CWE
NIST CWE-79
Changed
Reference Type
https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176&languageCode=en&Preview=true No Types Assigned
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below.
Incomplete or wrong received APDU frame layout may
cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer
with wrong length information of APDU or delayed reception
of data octets.
Only communication link of affected HCI IEC 60870-5-104
is blocked. If attack sequence stops the communication to
the previously attacked link g
Added
Reference
Hitachi ABB Power Grids https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176&languageCode=en&Preview=true [No types assigned]
Quick Info
CVE Dictionary Entry: CVE-2023-5768 NVD
Published Date: 12/04/2023 NVD
Last Modified: 12/07/2023
Source: Hitachi Energy