CVE-2024-25088
Detail
Modified After Enrichment
This CVE record has been updated after NVD enrichment efforts were completed. Enrichment data supplied by the NVD may require amendment due to these changes.
Description
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code.
Metrics
CVSS Version 4.0
CVSS Version 3.x
CVSS Version 2.0
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
CVSS 4.0 Severity and Vector Strings:
NVD assessment
not yet provided.
CVSS 3.x Severity and Vector Strings:
Vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0 Severity and Vector Strings:
NVD assessment
not yet provided.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected] .
Weakness Enumeration
CWE-ID
CWE Name
Source
NVD-CWE-noinfo
Insufficient Information
NIST
CWE-269
Improper Privilege Management
CISA-ADP
Change History
6 change records found show changes
CVE Modified by CISA-ADP
6/17/2026 3:15:28 AM
Action
Type
Old Value
New Value
Added
Affected
[{"vendor":"jungo","product":"windriver","defaultStatus":"unknown","cpes":["cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*"],"versions":[{"version":"0","lessThan":"12.5.1","versionType":"custom","status":"affected"}]}]
Added
SSVC
{"timestamp":"2024-07-08T20:13:12.712262Z","id":"CVE-2024-25088","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}
CVE Modified by MITRE
6/17/2026 3:15:28 AM
Action
Type
Old Value
New Value
Added
Affected
[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]
CVE Modified by CVE
11/21/2024 4:00:13 AM
Action
Type
Old Value
New Value
Added
Reference
https://jungo.com/windriver/versions/
Added
Reference
https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04
Added
Reference
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf
CVE Modified by CISA-ADP
8/01/2024 9:47:33 AM
Action
Type
Old Value
New Value
Added
CVSS V3.1
CISA-ADP AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Added
CWE
CISA-ADP CWE-269
Initial Analysis by NIST
7/05/2024 1:04:50 PM
Action
Type
Old Value
New Value
Added
CVSS V3.1
NIST AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Added
CWE
NIST NVD-CWE-noinfo
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*
OR
cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*
Added
CPE Configuration
OR
*cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:* versions up to (excluding) 12.5.1
Added
CPE Configuration
OR
*cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:mx_opc_server_da\/ua:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:px_developer\/monitor_tool:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*
*cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*
Changed
Reference Type
https://jungo.com/windriver/versions/ No Types Assigned
https://jungo.com/windriver/versions/ Release Notes
Changed
Reference Type
https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04 No Types Assigned
https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04 Third Party Advisory, US Government Resource
Changed
Reference Type
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf No Types Assigned
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf Third Party Advisory
New CVE Received from MITRE
7/02/2024 12:15:04 PM
Action
Type
Old Value
New Value
Added
Description
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code.
Added
Reference
MITRE https://jungo.com/windriver/versions/ [No types assigned]
Added
Reference
MITRE https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04 [No types assigned]
Added
Reference
MITRE https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf [No types assigned]
Quick Info
CVE Dictionary Entry: CVE-2024-25088 NVD
Published Date: 07/02/2024 NVD
Last Modified: 06/17/2026
Source: MITRE