NIST has updated the NVD program announcement page with additional information regarding recent concerns and the temporary delays in enrichment efforts.
CVE-2024-29206 Detail
Awaiting Analysis
This vulnerability is currently awaiting analysis. DescriptionAn Improper Access Control could allow a malicious actor authenticated in the API to enable Android Debug Bridge (ADB) and make unsupported changes to the system. Affected Products: UniFi Connect EV Station (Version 1.1.18 and earlier) UniFi Connect EV Station Pro (Version 1.1.18 and earlier) UniFi Access G2 Reader Pro (Version 1.2.172 and earlier) UniFi Access Reader Pro (Version 2.7.238 and earlier) UniFi Access Intercom (Version 1.0.66 and earlier) UniFi Access Intercom Viewer (Version 1.0.5 and earlier) UniFi Connect Display (Version 1.9.324 and earlier) UniFi Connect Display Cast (Version 1.6.225 and earlier) Mitigation: Update UniFi Connect Application to Version 3.10.7 or later. Update UniFi Connect EV Station to Version 1.2.15 or later. Update UniFi Connect EV Station Pro to Version 1.2.15 or later. Update UniFi Access G2 Reader Pro Version 1.3.37 or later. Update UniFi Access Reader Pro Version 2.8.19 or later. Update UniFi Access Intercom Version 1.1.32 or later. Update UniFi Access Intercom Viewer Version 1.1.6 or later. Update UniFi Connect Display to Version 1.11.348 or later. Update UniFi Connect Display Cast to Version 1.8.255 or later. Severity
CVSS 4.0 Severity and Metrics:
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA. Note: NVD Analysts have not published a CVSS score for this CVE at this time. NVD Analysts use publicly available information at the time of analysis to associate CVSS vector strings. References to Advisories, Solutions, and ToolsBy selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.
Weakness Enumeration
Quick InfoCVE Dictionary Entry:CVE-2024-29206 NVD Published Date: 05/07/2024 NVD Last Modified: 05/07/2024 Source: HackerOne |