U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Vulnerability Change Records for CVE-2024-30321

Change History

CVE Modified by CISA-ADP 6/17/2026 3:26:43 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"siemens","product":"simatic_pcs_7","defaultStatus":"unknown","cpes":["cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*"],"versions":[{"version":"9.1","lessThan":"10","versionType":"custom","status":"affected"}]},{"vendor":"siemens","product":"simatic_wincc","defaultStatus":"unknown","cpes":["cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"],"versions":[{"version":"7.4","lessThan":"7.4_sp1_update_23","versionType":"custom","status":"affected"},{"version":"7.5","lessThan":"7.5_sp2_update_17","versionType":"custom","status":"affected"},{"version":"8.0","lessThan":"8.0_update_5","versionType":"custom","status":"affected"}]},{"vendor":"siemens","product":"simatic_wincc","defaultStatus":"unknown","cpes":["cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"],"versions":[{"version":"7.4","lessThan":"7.4_sp1_update_23","versionType":"custom","status":"affected"},{"version":"7.5","lessThan":"7.5_sp2_update_17","versionType":"custom","status":"affected"},{"version":"8.0","lessThan":"8.0_update_5","versionType":"custom","status":"affected"}]},{"vendor":"siemens","product":"simatic_wincc","defaultStatus":"unknown","cpes":["cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"],"versions":[{"version":"7.4","lessThan":"7.4_sp1_update_23","versionType":"custom","status":"affected"},{"version":"7.5","lessThan":"7.5_sp2_update_17","versionType":"custom","status":"affected"},{"version":"8.0","lessThan":"8.0_update_5","versionType":"custom","status":"affected"}]},{"vendor":"siemens","product":"simatic_wincc_runtime_professional","defaultStatus":"unknown","cpes":["cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*"],"versions":[{"version":"18","lessThan":"19","versionType":"custom","status":"affected"},{"version":"19","lessThan":"19_update_2","versionType":"custom","status":"affected"}]},{"vendor":"siemens","product":"simatic_wincc_runtime_professional","defaultStatus":"unknown","cpes":["cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*"],"versions":[{"version":"18","lessThan":"19","versionType":"custom","status":"affected"},{"version":"19","lessThan":"19_update_2","versionType":"custom","status":"affected"}]}]
Added SSVC

                  
                
              
{"timestamp":"2024-08-19T16:20:35.487955Z","id":"CVE-2024-30321","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}

CVE Modified by Siemens AG 6/17/2026 3:26:43 AM

Action Type Old Value New Value
Added Affected

                  
                
              
[{"vendor":"Siemens","product":"SIMATIC PCS 7 V9.1","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V9.1 SP2 UC05","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional V18","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V18 Update 5","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional V19","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V19 Update 2","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V7.4","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.4 SP1 Update 23","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V7.5","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V7.5 SP2 Update 17","versionType":"custom","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC V8.0","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"V8.0 Update 5","versionType":"custom","status":"affected"}]}]