An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account.
When the console cable is disconnected, the logged in user is not logged out. This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges.
This issue affects Junos OS Evolved:
* from 23.2R2-EVO before 23.2R2-S1-EVO,
* from 23.4R1-EVO before 23.4R2-EVO.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
CVE Modified by Juniper Networks, Inc.6/17/2026 3:42:05 AM
Action
Type
Old Value
New Value
Added
Affected
[{"vendor":"Juniper Networks","product":"Junos OS Evolved","defaultStatus":"unaffected","versions":[{"version":"23.2R2-EVO","lessThan":"23.2R2-S1-EVO","versionType":"semver","status":"affected"},{"version":"23.4R1-EVO","lessThan":"23.4R2-EVO","versionType":"semver","status":"affected"}]}]
Initial Analysis by NIST2/07/2025 2:36:39 PM
Action
Type
Old Value
New Value
Added
CWE
NIST NVD-CWE-Other
Added
CPE Configuration
OR
*cpe:2.3:o:juniper:junos_os_evolved:23.2:r2:*:*:*:*:*:*
*cpe:2.3:o:juniper:junos_os_evolved:23.4:r1:*:*:*:*:*:*
*cpe:2.3:o:juniper:junos_os_evolved:23.4:r1-s1:*:*:*:*:*:*
*cpe:2.3:o:juniper:junos_os_evolved:23.4:r1-s2:*:*:*:*:*:*
Changed
Reference Type
https://supportportal.juniper.net/JSA82977 No Types Assigned
New CVE Received from Juniper Networks, Inc.7/10/2024 7:15:10 PM
Action
Type
Old Value
New Value
Added
Description
An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account.
When the console cable is disconnected, the logged in user is not logged out. This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges.
This issue affects Junos OS Evolved:
* from 23.2R2-EVO before 23.2R2-S1-EVO,
* from 23.4R1-EVO before 23.4R2-EVO.
Added
CVSS V4.0
Juniper Networks, Inc. CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Added
CVSS V3.1
Juniper Networks, Inc. AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Added
CWE
Juniper Networks, Inc. CWE-1263
Added
Reference
Juniper Networks, Inc. https://supportportal.juniper.net/JSA82977 [No types assigned]
Quick Info
CVE Dictionary Entry: CVE-2024-39512 NVD
Published Date: 07/10/2024 NVD
Last Modified: 06/17/2026
Source: Juniper Networks, Inc.