This CVE record has recently been published to the CVE List and has been included within the NVD dataset. DescriptionVasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA and SaaS deployments) provision the appliance with the network account credentials in clear-text inside /etc/issue, and the file is world-readable by default. An attacker with local shell access can read /etc/issue to obtain the network account username and password. Using the network account an attacker can change network parameters via the appliance interface, enabling local misconfiguration, network disruption or further escalation depending on deployment. Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
References to Advisories, Solutions, and ToolsBy selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to [email protected]. Weakness Enumeration
Quick InfoCVE Dictionary Entry:CVE-2025-34200 NVD Published Date: 09/19/2025 NVD Last Modified: 09/19/2025 Source: VulnCheck |