Issue summary: A specially crafted PKCS#7 or S/MIME signed message could
trigger a use-after-free during PKCS#7 signature verification.
Impact summary: A use-after-free may result in process crashes, heap
corruption, or potentially remote code execution.
When processing a PKCS#7 or S/MIME signed message, if the SignedData
digestAlgorithms field is present as an empty ASN.1 SET, OpenSSL may
incorrectly free a caller-owned BIO during PKCS7_verify(). A subsequent
use of the BIO by the calling application results in a use-after-free
condition.
In the common case this occurs when the application later calls
BIO_free() on the BIO originally passed to PKCS7_verify(). Depending
on allocator behavior and application-specific BIO usage patterns, this
may result in a crash or other memory corruption. In some application
contexts this may potentially be exploitable for remote code execution.
Applications that process PKCS#7 or S/MIME signed messages using OpenSSL
PKCS#7 APIs may be affected. Applications using the CMS APIs for this
processing are not affected.
The FIPS modules in 4.0, 3.6, 3.5, 3.4, and 3.0 are not affected by this
issue, as the affected code is outside the OpenSSL FIPS module boundary.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
OR
*cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* versions from (including) 1.0.2 up to (excluding) 1.0.2zq
*cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* versions from (including) 1.1.1 up to (excluding) 1.1.1zh
*cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* versions from (including) 3.0.0 up to (excluding) 3.0.21
*cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* versions from (including) 3.4.0 up to (excluding) 3.4.6
*cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* versions from (including) 3.5.0 up to (excluding) 3.5.7
*cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* versions from (including) 3.6.0 up to (excluding) 3.6.3
*cpe:2.3:a:openssl:openssl:4.0.0:-:*:*:*:*:*:*
New CVE Received from OpenSSL Software Foundation6/09/2026 1:17:19 PM
Action
Type
Old Value
New Value
Added
Description
Issue summary: A specially crafted PKCS#7 or S/MIME signed message could
trigger a use-after-free during PKCS#7 signature verification.
Impact summary: A use-after-free may result in process crashes, heap
corruption, or potentially remote code execution.
When processing a PKCS#7 or S/MIME signed message, if the SignedData
digestAlgorithms field is present as an empty ASN.1 SET, OpenSSL may
incorrectly free a caller-owned BIO during PKCS7_verify(). A subsequent
use of the BIO by the calling application results in a use-after-free
condition.
In the common case this occurs when the application later calls
BIO_free() on the BIO originally passed to PKCS7_verify(). Depending
on allocator behavior and application-specific BIO usage patterns, this
may result in a crash or other memory corruption. In some application
contexts this may potentially be exploitable for remote code execution.
Applications that process PKCS#7 or S/MIME signed messages using OpenSSL
PKCS#7 APIs may be affected. Applications using the CMS APIs for this
processing are not affected.
The FIPS modules in 4.0, 3.6, 3.5, 3.4, and 3.0 are not affected by this
issue, as the affected code is outside the OpenSSL FIPS module boundary.