You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions), STEP 7 - Micro/WIN SMART (All versions), SMART PC Access V2.0, SIMATIC Automation Tool (All versions), SIMATIC WinCC (All versions), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions), Security Configuration Tool (SCT) (All versions), SINEMA Server (All versions), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions before V2.3), SMART PC Access V2.0, SIMATIC Automation Tool (All versions before V3.0), SIMATIC WinCC (V7.2 and prior, V7.3 before Update 15, and V7.4 before SP1 Upd1), SIMATIC PCS 7 (All versions before 9.0), SIMATIC NET PC-Software (All versions before V14 SP1), Primary Setup Tool (PST) (All versions before V4.2HF1), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions before V14), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions before V4.7 SP4 HF2), and SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
A vulnerability has been identified in Primary Setup Tool (PST), SIMATIC Automation Tool, SIMATIC NET PC-Software, SIMATIC PCS 7, SIMATIC STEP 7 (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) V14, SIMATIC STEP 7 V5.X, SIMATIC WinAC RTX 2010 SP2, SIMATIC WinAC RTX F 2010 SP2, SIMATIC WinCC (TIA Portal) V13, SIMATIC WinCC (TIA Portal) V14, SIMATIC WinCC V7.2 and prior, SIMATIC WinCC V7.3, SIMATIC WinCC V7.4, SIMATIC WinCC flexible 2008, SINAUT ST7CC, SINEMA Server, SINUMERIK 808D Programming Tool, SMART PC Access, STEP 7 - Micro/WIN SMART, Security Configuration Tool (SCT). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.
CVE Modified by Siemens AG12/29/2017 9:29:04 PM
Action
Type
Old Value
New Value
Changed
Description
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions before V2.3), SMART PC Access V2.0, SIMATIC Automation Tool (All versions before V3.0), SIMATIC WinCC (All versions before V7.4 SP1 Upd1), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions before V4.2HF1), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions before V14), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions before V4.7 SP4 HF2), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions before V2.3), SMART PC Access V2.0, SIMATIC Automation Tool (All versions before V3.0), SIMATIC WinCC (V7.2 and prior, V7.3 before Update 15, and V7.4 before SP1 Upd1), SIMATIC PCS 7 (All versions before 9.0), SIMATIC NET PC-Software (All versions before V14 SP1), Primary Setup Tool (PST) (All versions before V4.2HF1), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions before V14), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions before V4.7 SP4 HF2), and SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
CVE Modified by Siemens AG8/16/2017 9:34:29 PM
Action
Type
Old Value
New Value
Changed
Description
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions), SMART PC Access V2.0, SIMATIC Automation Tool (All versions), SIMATIC WinCC (All versions before V7.4 SP1 Upd1), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions before V2.3), SMART PC Access V2.0, SIMATIC Automation Tool (All versions before V3.0), SIMATIC WinCC (All versions before V7.4 SP1 Upd1), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions before V4.2HF1), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions before V14), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions before V4.7 SP4 HF2), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
CVE Modified by Siemens AG6/08/2017 9:29:02 PM
Action
Type
Old Value
New Value
Changed
Description
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions), SMART PC Access V2.0, SIMATIC Automation Tool (All versions), SIMATIC WinCC (All versions bevore V7.4 SP1 Upd1), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions), SMART PC Access V2.0, SIMATIC Automation Tool (All versions), SIMATIC WinCC (All versions before V7.4 SP1 Upd1), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
CVE Modified by Siemens AG6/07/2017 9:29:03 PM
Action
Type
Old Value
New Value
Changed
Description
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions), STEP 7 - Micro/WIN SMART (All versions), SMART PC Access V2.0, SIMATIC Automation Tool (All versions), SIMATIC WinCC (All versions), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions), Security Configuration Tool (SCT) (All versions), SINEMA Server (All versions), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.
Siemens SIMATIC WinCC (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 (TIA Portal) (V13 all versions before SP2 and V14 before SP1), SIMATIC STEP 7 V5.X (All versions before V5.6), STEP 7 - Micro/WIN SMART (All versions), SMART PC Access V2.0, SIMATIC Automation Tool (All versions), SIMATIC WinCC (All versions bevore V7.4 SP1 Upd1), SIMATIC PCS 7 (All versions), SIMATIC NET PC-Software (All versions), Primary Setup Tool (PST) (All versions), Security Configuration Tool (SCT) (All versions before V5.0), SINEMA Server (All versions), SINAUT ST7CC (All versions), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SINUMERIK 808D Programming Tool (All versions), SIMATIC WinCC flexible 2008 (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet.