CVE-2021-0257 Detail
Modified
This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided. DescriptionOn Juniper Networks MX Series and EX9200 Series platforms with Trio-based MPCs (Modular Port Concentrators) where Integrated Routing and Bridging (IRB) interfaces are configured and mapped to a VPLS instance or a Bridge-Domain, certain Layer 2 network events at Customer Edge (CE) devices may cause memory leaks in the MPC of Provider Edge (PE) devices which can cause an out of memory condition and MPC restart. When this issue occurs, there will be temporary traffic interruption until the MPC is restored. An administrator can use the following CLI command to monitor the status of memory usage level of the MPC: user@device> show system resource-monitor fpc FPC Resource Usage Summary Free Heap Mem Watermark : 20 % Free NH Mem Watermark : 20 % Free Filter Mem Watermark : 20 % * - Watermark reached Slot # % Heap Free RTT Average RTT 1 87 PFE # % ENCAP mem Free % NH mem Free % FW mem Free 0 NA 88 99 1 NA 89 99 When the issue is occurring, the value of “% NH mem Free” will go down until the MPC restarts. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines), including MX-MPC1-3D, MX-MPC1E-3D, MX-MPC2-3D, MX-MPC2E-3D, MPC-3D-16XGE, and CHAS-MXxx Series MPCs. No other products or platforms are affected by this issue. This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3 versions prior to 17.3R3-S10; 17.4 versions prior to 17.4R3-S3; 18.2 versions prior to 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R3-S6; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R2-S2, 19.4R3; 20.2 versions prior to 20.2R1-S3, 20.2R2; 20.3 versions prior to 20.3R1-S1,, 20.3R2. This issue does not affect Juniper Networks Junos OS: 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R3-S2; 18.1; 18.2 versions prior to 18.2R3-S4; 18.3 versions prior to 18.3R3-S2; 18.4 versions prior to 18.4R3-S1; 19.1; 19.2 versions prior to 19.2R2; 19.3 versions prior to 19.3R3; 19.4 versions prior to 19.4R2. Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
CVSS 4.0 Severity and Vector Strings:
References to Advisories, Solutions, and ToolsBy selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.
Weakness Enumeration
Known Affected Software Configurations Switch to CPE 2.2CPEs loading, please wait.
Denotes Vulnerable Software Quick InfoCVE Dictionary Entry:CVE-2021-0257 NVD Published Date: 04/22/2021 NVD Last Modified: 11/21/2024 Source: Juniper Networks, Inc. |