Current Description
Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0.
Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
CVE Modified by Computer Emergency Response Team of the Republic of Turkey9/16/2024 11:15:38 PM
Action
Type
Old Value
New Value
Changed
Description
Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0.
Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0.
CVE Modified by Computer Emergency Response Team of the Republic of Turkey5/14/2024 5:26:10 AM
Action
Type
Old Value
New Value
Modified Analysis by NIST1/26/2024 1:57:54 PM
Action
Type
Old Value
New Value
CVE Modified by Computer Emergency Response Team of the Republic of Turkey3/26/2023 4:15:07 PM
Action
Type
Old Value
New Value
Added
CWE
Computer Emergency Response Team of the Republic of Turkey CWE-89
Removed
CWE
Computer Emergency Response Team of the Republic of Turkey CWE-233
CVE Modified by Computer Emergency Response Team of the Republic of Turkey2/08/2023 3:15:08 AM
Action
Type
Old Value
New Value
Changed
Description
Due to improper sanitization iPack SCADA Automation software suffers from a remote SQL injection vulnerability. An unauthenticated attacker with the web access is able to extract critical information from the system.
Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0.
Added
CVSS V3.1
Computer Emergency Response Team of the Republic of Turkey AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Removed
CVSS V3.1
Computer Emergency Response Team of the Republic of Turkey AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
Added
CWE
Computer Emergency Response Team of the Republic of Turkey CWE-233
Removed
CWE
Computer Emergency Response Team of the Republic of Turkey CWE-89
Removed
CVSS V3.1 Reason
A-No limiting factors
Removed
CVSS V3.1 Reason
I-No limiting factors
Initial Analysis by NIST11/17/2021 3:16:04 PM
Action
Type
Old Value
New Value
Added
CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Added
CVSS V2
NIST (AV:N/AC:L/Au:N/C:P/I:P/A:P)
Added
CWE
NIST CWE-89
Added
CPE Configuration
OR
*cpe:2.3:a:ipack:scada_automation:*:*:*:*:*:*:*:* versions up to (excluding) 1.1.0
Changed
Reference Type
https://github.com/paradessia/cve/blob/main/Ipack-Scada-Automation.txt No Types Assigned
https://github.com/paradessia/cve/blob/main/Ipack-Scada-Automation.txt Exploit, Third Party Advisory
Quick Info
CVE Dictionary Entry: CVE-2021-3958 NVD
Published Date: 11/16/2021 NVD
Last Modified: 06/17/2026
Source: Computer Emergency Response Team of the Republic of Turkey