A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
OR
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 8.2
*cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* versions up to (including) 7.4
*cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_win
OR
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 8.2
*cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* versions up to (excluding) 7.4
*cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_win
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 and earlier (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via pub
OR
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 8.2
*cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* versions up to (including) 7.4
*cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_win
Added
CVSS V2
NIST (AV:N/AC:L/Au:S/C:P/I:N/A:N)
Added
CVSS V3.1
NIST AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Added
CWE
NIST CWE-307
Changed
Reference Type
https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf No Types Assigned