Current Description
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16.
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path.
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16.
http://packetstormsecurity.com/files/168116/FLIR-AX8-1.46.16-Traversal-Access-Control-Command-Injection-XSS.html Broken Link
http://packetstormsecurity.com/files/168116/FLIR-AX8-1.46.16-Traversal-Access-Control-Command-Injection-XSS.html Exploit, Third Party Advisory, VDB Entry
Changed
Reference Type
https://www.zeroscience.mk/en/vulnerabilities/ZSL-2018-5493.php No Types Assigned
https://www.zeroscience.mk/en/vulnerabilities/ZSL-2018-5493.php Third Party Advisory