This CVE record has been marked for NVD enrichment efforts.
Description
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service conditions. Attackers can compromise network communications to modify device settings such as alarm states or alarm limits, or overwhelm the system with excessive network traffic causing the Cockpit or M540 to reboot and lose network functionality.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
Title: Infinity de Dräger, Description: Dräger Infinity Acute Care System y monitores de paciente Standalone Infinity M540 versiones VG4.1.1, VG4.0.3, e inferiores (con VG4.2 parcialmente afectado) contienen una vulnerabilidad en el manejo de mensajes de red que permite a atacantes remotos inyectar datos falsificados o manipulados y causar condiciones de denegación de servicio. Los atacantes pueden comprometer las comunicaciones de red para modificar la configuración del dispositivo, como los estados de alarma o los límites de alarma, o sobrecargar el sistema con tráfico de red excesivo, lo que provoca que el Cockpit o el M540 se reinicien y pierdan la funcionalidad de red.
New CVE Received from VulnCheck6/02/2026 6:16:15 PM
Action
Type
Old Value
New Value
Added
Description
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service conditions. Attackers can compromise network communications to modify device settings such as alarm states or alarm limits, or overwhelm the system with excessive network traffic causing the Cockpit or M540 to reboot and lose network functionality.