Description
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call)
communication protocol in the affected products do not
properly handle certain unorganized RPC messages. An
attacker could use this vulnerability to cause a denial of service
condition in the RPC server.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
OR
*cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:* versions up to (including) 9.1
*cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:* versions up to (including) 9.1
*cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* versions up to (including) 9.1
*cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:* versions up to (including) 9.1
*cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*
*cpe:2.3:a:siemens:simatic_wincc:8.0
Changed
Reference Type
https://cert-portal.siemens.com/productcert/html/ssa-753746.html No Types Assigned
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure ca
Added
CVSS V4.0
Siemens AG CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X