This CVE record is not being prioritized for NVD enrichment efforts due to resource or other concerns.
Description
Uncontrolled Search Path Element Vulnerability in Setting and Operation Application for Lighting Control System MILCO.S Setting Application all versions, MILCO.S Setting Application (IR) all versions, MILCO.S Easy Setting Application (IR) all versions, and MILCO.S Easy Switch Application (IR) all versions allows a local attacker to execute malicious code by having installer to load a malicious DLL. However, if the signer name "Mitsubishi Electric Lighting" appears on the "Digital Signatures" tab of the properties for "MILCO.S Lighting Control.exe", the application is a fixed one. This vulnerability only affects when the installer is run, not after installation. If a user downloads directly from Mitsubishi Electric website and installs the affected product, there is no risk of malicious code being introduced.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
CVE Modified by Mitsubishi Electric Corporation6/17/2026 4:27:39 AM
Action
Type
Old Value
New Value
Added
Affected
[{"vendor":"Mitsubishi Electric Corporation","product":"MILCO.S Setting Application","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Mitsubishi Electric Corporation","product":"MILCO.S Setting Application (IR)","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Mitsubishi Electric Corporation","product":"MILCO.S Easy Setting Application (IR)","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Mitsubishi Electric Corporation","product":"MILCO.S Easy Switch Application (IR)","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]}]
CVE Modified by Mitsubishi Electric Corporation11/27/2025 12:16:00 AM
Action
Type
Old Value
New Value
Added
CVSS V3.1
AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
Removed
CVSS V3.1
AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
CVE Modified by Mitsubishi Electric Corporation11/18/2025 4:15:46 AM
Action
Type
Old Value
New Value
Changed
Description
Malicious Code Execution Vulnerability in Setting and Operation Application for Lighting Control System MILCO.S Setting Application all versions, MILCO.S Setting Application (IR) all versions, MILCO.S Easy Setting Application (IR) all versions, and MILCO.S Easy Switch Application (IR) all versions allows a local attacker to execute malicious code by having installer to load a malicious DLL. However, if the signer name "Mitsubishi Electric Lighting" appears on the "Digital Signatures" tab of the properties for "MILCO.S Lighting Control.exe", the application is a fixed one. This vulnerability only affects when the installer is run, not after installation. If a user downloads directly from our company website and installs the affected product, there is no risk of malicious code being introduced.
Uncontrolled Search Path Element Vulnerability in Setting and Operation Application for Lighting Control System MILCO.S Setting Application all versions, MILCO.S Setting Application (IR) all versions, MILCO.S Easy Setting Application (IR) all versions, and MILCO.S Easy Switch Application (IR) all versions allows a local attacker to execute malicious code by having installer to load a malicious DLL. However, if the signer name "Mitsubishi Electric Lighting" appears on the "Digital Signatures" tab of the properties for "MILCO.S Lighting Control.exe", the application is a fixed one. This vulnerability only affects when the installer is run, not after installation. If a user downloads directly from Mitsubishi Electric website and installs the affected product, there is no risk of malicious code being introduced.
New CVE Received from Mitsubishi Electric Corporation11/18/2025 3:15:49 AM
Action
Type
Old Value
New Value
Added
Description
Malicious Code Execution Vulnerability in Setting and Operation Application for Lighting Control System MILCO.S Setting Application all versions, MILCO.S Setting Application (IR) all versions, MILCO.S Easy Setting Application (IR) all versions, and MILCO.S Easy Switch Application (IR) all versions allows a local attacker to execute malicious code by having installer to load a malicious DLL. However, if the signer name "Mitsubishi Electric Lighting" appears on the "Digital Signatures" tab of the properties for "MILCO.S Lighting Control.exe", the application is a fixed one. This vulnerability only affects when the installer is run, not after installation. If a user downloads directly from our company website and installs the affected product, there is no risk of malicious code being introduced.