Description

A weakness has been identified in Edimax BR-6428nC up to 1.16. This affects an unknown function of the file /goform/setWAN of the component Web Interface. This manipulation of the argument pppUserName/pptpUserName causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.


Metrics

NVD enrichment efforts reference publicly available information to associate vector strings. CVSS information contributed by other sources is also displayed.
CVSS 4.0 Severity and Vector Strings:

NIST CVSS score
NIST: NVD
N/A
NVD assessment not yet provided.

Nist CVSS score does not match with CNA score
CNA:  VulDB
CVSS-BT 2.1 LOW
Vector:  CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to [email protected].

URL Source(s) Tag(s)
https://tzh00203.notion.site/Edimax-BR-6428nC-v1-16-setWAN-pppUserName-Command-Injection-33db5c52018a80dab299ef508e810d00 VulDB
https://tzh00203.notion.site/Edimax-BR-6428nC-v1-16-setWAN-pptpUserName-Command-Injection-33db5c52018a80949cfbcc2091340c80 VulDB
https://vuldb.com/submit/801597 VulDB
https://vuldb.com/submit/801598 VulDB
https://vuldb.com/vuln/360842 VulDB
https://vuldb.com/vuln/360842/cti VulDB

Weakness Enumeration

CWE-ID CWE Name Source
CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') VulDB  
CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection') VulDB  

Change History

1 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2026-7683
NVD Published Date:
05/03/2026
NVD Last Modified:
05/03/2026
Source:
VulDB