Search Results (Refine Search)
- CPE Product Version: cpe:/a:siemens:wincc:7.2
Vuln ID | Summary | CVSS Severity |
---|---|---|
CVE-2023-30897 |
A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges. Published: June 13, 2023; 5:15:17 AM -0400 |
V3.1: 7.8 HIGH V2.0:(not available) |
CVE-2017-12069 |
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker. Published: August 30, 2017; 3:29:00 PM -0400 |
V3.0: 8.2 HIGH V2.0: 6.4 MEDIUM |
CVE-2015-2823 |
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. Published: April 08, 2015; 12:59:01 PM -0400 |
V3.x:(not available) V2.0: 6.8 MEDIUM |
CVE-2015-2822 |
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. Published: April 08, 2015; 12:59:00 PM -0400 |
V3.x:(not available) V2.0: 4.3 MEDIUM |
CVE-2014-4686 |
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. Published: July 24, 2014; 10:55:08 AM -0400 |
V3.x:(not available) V2.0: 6.8 MEDIUM |
CVE-2014-4685 |
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. Published: July 24, 2014; 10:55:08 AM -0400 |
V3.x:(not available) V2.0: 4.6 MEDIUM |
CVE-2014-4684 |
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. Published: July 24, 2014; 10:55:08 AM -0400 |
V3.x:(not available) V2.0: 6.0 MEDIUM |
CVE-2014-4683 |
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. Published: July 24, 2014; 10:55:08 AM -0400 |
V3.x:(not available) V2.0: 4.9 MEDIUM |
CVE-2014-4682 |
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. Published: July 24, 2014; 10:55:08 AM -0400 |
V3.x:(not available) V2.0: 5.0 MEDIUM |
CVE-2013-3959 |
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. Published: June 14, 2013; 3:55:01 PM -0400 |
V3.x:(not available) V2.0: 4.0 MEDIUM |
CVE-2013-3958 |
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. Published: June 14, 2013; 3:55:01 PM -0400 |
V3.x:(not available) V2.0: 7.5 HIGH |
CVE-2013-3957 |
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Published: June 14, 2013; 3:55:01 PM -0400 |
V3.x:(not available) V2.0: 7.5 HIGH |
CVE-2011-4879 |
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. Published: February 03, 2012; 3:55:02 PM -0500 |
V3.x:(not available) V2.0: 8.5 HIGH |
CVE-2011-4878 |
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. Published: February 03, 2012; 3:55:02 PM -0500 |
V3.x:(not available) V2.0: 7.8 HIGH |
CVE-2011-4512 |
CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. Published: February 03, 2012; 3:55:01 PM -0500 |
V3.x:(not available) V2.0: 5.0 MEDIUM |
CVE-2011-4511 |
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. Published: February 03, 2012; 3:55:01 PM -0500 |
V3.x:(not available) V2.0: 4.3 MEDIUM |
CVE-2011-4510 |
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. Published: February 03, 2012; 3:55:01 PM -0500 |
V3.x:(not available) V2.0: 4.3 MEDIUM |
CVE-2011-4508 |
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. Published: February 03, 2012; 3:55:01 PM -0500 |
V3.x:(not available) V2.0: 9.3 HIGH |