U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Results (Refine Search)

Search Parameters:
  • Results Type: Overview
  • Keyword (text search): cpe:2.3:o:juniper:junos:17.1:r3-s1:*:*:*:*:*:*
There are 17 matching records.
Displaying matches 1 through 17.
Vuln ID Summary CVSS Severity
CVE-2022-22226

In VxLAN scenarios on EX4300-MP, EX4600, QFX5000 Series devices an Uncontrolled Memory Allocation vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated adjacently located attacker sending specific packets to cause a Denial of Service (DoS) condition by crashing one or more PFE's when they are received and processed by the device. Upon automatic restart of the PFE, continued processing of these packets will cause the memory leak to reappear. Depending on the volume of packets received the attacker may be able to create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on EX4300-MP, EX4600, QFX5000 Series: 17.1 version 17.1R1 and later versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S7, 19.2R3-S1; 19.3 versions prior to 19.3R2-S6, 19.3R3-S1; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2. This issue does not affect Junos OS versions prior to 17.1R1.

Published: October 17, 2022; 11:15:09 PM -0400
V3.1: 6.5 MEDIUM
V2.0:(not available)
CVE-2022-22160

An Unchecked Error Condition vulnerability in the subscriber management daemon (smgd) of Juniper Networks Junos OS allows an unauthenticated adjacent attacker to cause a crash of and thereby a Denial of Service (DoS). In a subscriber management / broadband edge environment if a single session group configuration contains dual-stack and a pp0 interface, smgd will crash and restart every time a PPPoE client sends a specific message. This issue affects Juniper Networks Junos OS on MX Series: 16.1 version 16.1R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.

Published: January 18, 2022; 8:15:08 PM -0500
V3.1: 6.5 MEDIUM
V2.0: 2.9 LOW
CVE-2022-22154

In a Junos Fusion scenario an External Control of Critical State Data vulnerability in the Satellite Device (SD) control state machine of Juniper Networks Junos OS allows an attacker who is able to make physical changes to the cabling of the device to cause a denial of service (DoS). An SD can get rebooted and subsequently controlled by an Aggregation Device (AD) which does not belong to the original Fusion setup and is just connected to an extended port of the SD. To carry out this attack the attacker needs to have physical access to the cabling between the SD and the original AD. This issue affects: Juniper Networks Junos OS 16.1R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S7; 19.2 versions prior to 19.2R3-S4. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.

Published: January 18, 2022; 8:15:08 PM -0500
V3.1: 6.8 MEDIUM
V2.0: 4.6 MEDIUM
CVE-2021-0290

Improper Handling of Exceptional Conditions in Ethernet interface frame processing of Juniper Networks Junos OS allows an attacker to send specially crafted frames over the local Ethernet segment, causing the interface to go into a down state, resulting in a Denial of Service (DoS) condition. The interface does not recover on its own and the FPC must be reset manually. Continued receipt and processing of these frames will create a sustained Denial of Service (DoS) condition. This issue is platform-specific and affects the following platforms and line cards: * MPC7E/8E/9E and MPC10E on MX240, MX480, MX960, MX2008, MX2010, and MX2020 * MX204, MX10003, MX10008, MX10016 * EX9200, EX9251 * SRX4600 No other products or platforms are affected by this vulnerability. An indication of this issue occurring can be seen in the system log messages, as shown below: user@host> show log messages | match "Failed to complete DFE tuning" fpc4 smic_phy_dfe_tuning_state: et-4/1/6 - Failed to complete DFE tuning (count 3) and interface will be in a permanently down state: user@host> show interfaces et-4/1/6 terse Interface Admin Link Proto Local Remote et-4/1/6 up down et-4/1/6.0 up down aenet --> ae101.0 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S7 on MX Series; 17.1R1 and later versions prior to 17.2R3-S3 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S11, 17.4R3-S1 on MX Series, SRX4600; 18.1 versions prior to 18.1R3-S10 on MX Series, EX9200 Series, SRX4600; 18.2 versions prior to 18.2R3-S3 on MX Series, EX9200 Series, SRX4600; 18.3 versions prior to 18.3R3-S1 on MX Series, EX9200 Series, SRX4600; 18.4 versions prior to 18.4R2-S3, 18.4R3 on MX Series, EX9200 Series, SRX4600; 19.1 versions prior to 19.1R2-S1, 19.1R3 on MX Series, EX9200 Series, SRX4600; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series, EX9200 Series, SRX4600; 19.3 versions prior to 19.3R2 on MX Series, EX9200 Series, SRX4600. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.

Published: July 15, 2021; 4:15:10 PM -0400
V3.1: 6.5 MEDIUM
V2.0: 3.3 LOW
CVE-2021-0283

A buffer overflow vulnerability in the TCP/IP stack of Juniper Networks Junos OS allows an attacker to send specific sequences of packets to the device thereby causing a Denial of Service (DoS). By repeatedly sending these sequences of packets to the device, an attacker can sustain the Denial of Service (DoS) condition. The device will abnormally shut down as a result of these sent packets. A potential indicator of compromise will be the following message in the log files: "eventd[13955]: SYSTEM_ABNORMAL_SHUTDOWN: System abnormally shut down" These issue are only triggered by traffic destined to the device. Transit traffic will not trigger these issues. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S19; 15.1 versions prior to 15.1R7-S10; 16.1 version 16.1R1 and later versions; 16.2 version 16.2R1 and later versions; 17.1 version 17.1R1 and later versions; 17.2 version 17.2R1 and later versions; 17.3 versions prior to 17.3R3-S12; 17.4 version 17.4R1 and later versions; 18.1 versions prior to 18.1R3-S13; 18.2 version 18.2R1 and later versions; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S7, 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2; 21.2 versions prior to 21.2R1-S1, 21.2R2.

Published: July 15, 2021; 4:15:10 PM -0400
V3.1: 7.5 HIGH
V2.0: 7.8 HIGH
CVE-2021-0275

A Cross-site Scripting (XSS) vulnerability in J-Web on Juniper Networks Junos OS allows an attacker to target another user's session thereby gaining access to the users session. The other user session must be active for the attack to succeed. Once successful, the attacker has the same privileges as the user. If the user has root privileges, the attacker may be able to gain full control of the device. This issue affects: Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15 on EX Series; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 15.1 versions prior to 15.1R7-S6 on EX Series; 15.1X49 versions prior to 15.1X49-D200 on SRX Series; 16.1 versions prior to 16.1R7-S7; 16.2 versions prior to 16.2R2-S11, 16.2R3; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3; 19.1 versions prior to 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S3, 19.2R2; 19.3 versions prior to 19.3R2.

Published: April 22, 2021; 4:15:10 PM -0400
V3.1: 8.8 HIGH
V2.0: 9.3 HIGH
CVE-2021-0272

A kernel memory leak in QFX10002-32Q, QFX10002-60C, QFX10002-72Q, QFX10008, QFX10016 devices Flexible PIC Concentrators (FPCs) on Juniper Networks Junos OS allows an attacker to send genuine packets destined to the device to cause a Denial of Service (DoS) to the device. On QFX10002-32Q, QFX10002-60C, QFX10002-72Q devices the device will crash and restart. On QFX10008, QFX10016 devices, depending on the number of FPCs involved in an attack, one more more FPCs may crash and traffic through the device may be degraded in other ways, until the attack traffic stops. A reboot is required to restore service and clear the kernel memory. Continued receipt and processing of these genuine packets will create a sustained Denial of Service (DoS) condition. On QFX10008, QFX10016 devices, an indicator of compromise may be the existence of DCPFE core files. You can also monitor PFE memory utilization for incremental growth: user@qfx-RE:0% cprod -A fpc0 -c "show heap 0" | grep -i ke 0 3788a1b0 3221225048 2417120656 804104392 24 Kernel user@qfx-RE:0% cprod -A fpc0 -c "show heap 0" | grep -i ke 0 3788a1b0 3221225048 2332332200 888892848 27 Kernel This issue affects: Juniper Networks Junos OS on QFX10002-32Q, QFX10002-60C, QFX10002-72Q, QFX10008, QFX10016: 16.1 versions 16.1R1 and above prior to 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R3-S2; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R3; 19.3 versions prior to 19.3R3; 19.4 versions prior to 19.4R3; 20.1 versions prior to 20.1R2. This issue does not affect releases prior to Junos OS 16.1R1. This issue does not affect EX Series devices. This issue does not affect Junos OS Evolved.

Published: April 22, 2021; 4:15:10 PM -0400
V3.1: 6.5 MEDIUM
V2.0: 6.1 MEDIUM
CVE-2021-0247

A Race Condition (Concurrent Execution using Shared Resource with Improper Synchronization) vulnerability in the firewall process (dfwd) of Juniper Networks Junos OS allows an attacker to bypass the firewall rule sets applied to the input loopback filter on any interfaces of a device. This issue is detectable by reviewing the PFE firewall rules, as well as the firewall counters and seeing if they are incrementing or not. For example: show firewall Filter: __default_bpdu_filter__ Filter: FILTER-INET-01 Counters: Name Bytes Packets output-match-inet 0 0 <<<<<< missing firewall packet count This issue affects: Juniper Networks Junos OS 14.1X53 versions prior to 14.1X53-D53 on QFX Series; 14.1 versions 14.1R1 and later versions prior to 15.1 versions prior to 15.1R7-S6 on QFX Series, PTX Series; 15.1X53 versions prior to 15.1X53-D593 on QFX Series; 16.1 versions prior to 16.1R7-S7 on QFX Series, PTX Series; 16.2 versions prior to 16.2R2-S11, 16.2R3 on QFX Series, PTX Series; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on QFX Series, PTX Series; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3 on QFX Series, PTX Series; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on QFX Series, PTX Series; 17.4 versions prior to 17.4R2-S9, 17.4R3 on QFX Series, PTX Series; 18.1 versions prior to 18.1R3-S9 on QFX Series, PTX Series; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3 on QFX Series, PTX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1 on QFX Series, PTX Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R2-S7, 18.4R3 on QFX Series, PTX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on QFX Series, PTX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on QFX Series, PTX Series.

Published: April 22, 2021; 4:15:09 PM -0400
V3.1: 5.5 MEDIUM
V2.0: 6.8 MEDIUM
CVE-2021-0245

A Use of Hard-coded Credentials vulnerability in Juniper Networks Junos OS on Junos Fusion satellite devices allows an attacker who is local to the device to elevate their privileges and take control of the device. This issue affects: Juniper Networks Junos OS Junos Fusion Satellite Devices. 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S12, 17.1R3-S2; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10; 17.4 version 17.4R3 and later versions; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2; 20.1 versions prior to 20.1R1-S1, 20.1R2. This issue does not affected Junos OS releases prior to 16.1R1 or all 19.2R3 and 19.4R3 release versions.

Published: April 22, 2021; 4:15:09 PM -0400
V3.1: 7.8 HIGH
V2.0: 7.2 HIGH
CVE-2021-0230

On Juniper Networks SRX Series devices with link aggregation (lag) configured, executing any operation that fetches Aggregated Ethernet (AE) interface statistics, including but not limited to SNMP GET requests, causes a slow kernel memory leak. If all the available memory is consumed, the traffic will be impacted and a reboot might be required. The following log can be seen if this issue happens. /kernel: rt_pfe_veto: Memory over consumed. Op 1 err 12, rtsm_id 0:-1, msg type 72 /kernel: rt_pfe_veto: free kmem_map memory = (20770816) curproc = kmd An administrator can use the following CLI command to monitor the status of memory consumption (ifstat bucket): user@device > show system virtual-memory no-forwarding | match ifstat Type InUse MemUse HighUse Limit Requests Limit Limit Size(s) ifstat 2588977 162708K - 19633958 <<<< user@device > show system virtual-memory no-forwarding | match ifstat Type InUse MemUse HighUse Limit Requests Limit Limit Size(s) ifstat 3021629 189749K - 22914415 <<<< This issue affects Juniper Networks Junos OS on SRX Series: 17.1 versions 17.1R3 and above prior to 17.3R3-S11; 17.4 versions prior to 17.4R3-S5; 18.2 versions prior to 18.2R3-S7, 18.2R3-S8; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S7, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R1-S2, 20.3R2. This issue does not affect Juniper Networks Junos OS prior to 17.1R3.

Published: April 22, 2021; 4:15:08 PM -0400
V3.1: 7.5 HIGH
V2.0: 5.0 MEDIUM
CVE-2021-0229

An uncontrolled resource consumption vulnerability in Message Queue Telemetry Transport (MQTT) server of Juniper Networks Junos OS allows an attacker to cause MQTT server to crash and restart leading to a Denial of Service (DoS) by sending a stream of specific packets. A Juniper Extension Toolkit (JET) application designed with a listening port uses the Message Queue Telemetry Transport (MQTT) protocol to connect to a mosquitto broker that is running on Junos OS to subscribe for events. Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects Juniper Networks Junos OS: 16.1R1 and later versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R2-S8, 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R1-S8, 18.4R2-S7, 18.4R3-S7; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R2-S1, 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R1-S1, 20.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.

Published: April 22, 2021; 4:15:08 PM -0400
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2021-0222

A vulnerability in Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) to the device by sending certain crafted protocol packets from an adjacent device with invalid payloads to the device. These crafted packets, which should be discarded, are instead replicated and sent to the RE. Over time, a Denial of Service (DoS) occurs. Continued receipt of these crafted protocol packets will cause an extended Denial of Service (DoS) condition, which may cause wider traffic impact due to protocol flapping. An indication of compromise is to check "monitor interface traffic" on the ingress and egress port packet counts. For each ingress packet, two duplicate packets are seen on egress. This issue can be triggered by IPv4 and IPv6 packets. This issue affects all traffic through the device. This issue affects: Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D53 on EX4300, QFX3500, QFX5100, EX4600; 15.1 versions prior to 15.1R7-S6 on EX4300, QFX3500, QFX5100, EX4600; 16.1 versions prior to 16.1R7-S7 on EX4300, QFX5100, EX4600; 17.1 versions prior to 17.1R2-S11 on EX4300, QFX5100, EX4600; 17.1 versions prior to 117.1R3-S2 on EX4300; 17.2 versions prior to 17.2R1-S9 on EX4300; 17.2 versions prior to 17.2R3-S3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on EX4300, QFX5100, EX4600, QFX5110, QFX5200; 17.4 versions prior to 17.4R2-S9, 17.4R3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200; 18.1 versions prior to 18.1R3-S9 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, EX2300, EX3400; 18.2 versions prior to 18.2R2-S7 on EX4300; 18.2 versions prior to 18.2R3-S3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, EX2300, EX3400; 18.3 versions prior to 18.3R2-S3, on EX4300; 18.3 versions prior to 18.3R1-S7, 18.3R3-S1 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on EX4300, QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 19.2 versions prior to 19.2R1-S4, 19.2R2 on EX4300; 19.2 versions prior to 19.2R1-S3, 19.2R2 on QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400; 19.3 versions prior to 19.3R2-S1, 19.3R3 on EX4300; 19.3 versions prior to 19.3R1-S1, 19.3R2, 19.3R3 on QFX5100, EX4600, QFX5110, QFX5200, QFX5210, QFX5120, EX4650, EX2300, EX3400;

Published: January 15, 2021; 1:15:15 PM -0500
V3.1: 7.4 HIGH
V2.0: 6.1 MEDIUM
CVE-2020-1656

The DHCPv6 Relay-Agent service, part of the Juniper Enhanced jdhcpd daemon shipped with Juniper Networks Junos OS has an Improper Input Validation vulnerability which will result in a Denial of Service (DoS) condition when a DHCPv6 client sends a specific DHPCv6 message allowing an attacker to potentially perform a Remote Code Execution (RCE) attack on the target device. Continuous receipt of the specific DHCPv6 client message will result in an extended Denial of Service (DoS) condition. If adjacent devices are also configured to relay DHCP packets, and are not affected by this issue and simply transparently forward unprocessed client DHCPv6 messages, then the attack vector can be a Network-based attack, instead of an Adjacent-device attack. No other DHCP services are affected. Receipt of the packet without configuration of the DHCPv6 Relay-Agent service, will not result in exploitability of this issue. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95; 14.1X53 versions prior to 14.1X53-D53; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S7; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R3-S3; 17.2X75 versions prior to 17.2X75-D44; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R2-S6, 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D435, 18.2X75-D60; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3; 19.1 versions prior to 19.1R1-S4, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2; 19.3 versions prior to 19.3R2.

Published: October 16, 2020; 5:15:12 PM -0400
V3.1: 8.8 HIGH
V2.0: 5.8 MEDIUM
CVE-2020-1641

A Race Condition vulnerability in Juniper Networks Junos OS LLDP implementation allows an attacker to cause LLDP to crash leading to a Denial of Service (DoS). This issue occurs when crafted LLDP packets are received by the device from an adjacent device. Multiple LACP flaps will occur after LLDP crashes. An indicator of compromise is to evaluate log file details for lldp with RLIMIT. Intervention should occur before 85% threshold of used KB versus maximum available KB memory is reached. show log messages | match RLIMIT | match lldp | last 20 Matching statement is " /kernel: %KERNEL-[number]: Process ([pid #],lldpd) has exceeded 85% of RLIMIT_DATA: " with [] as variable data to evaluate for. This issue affects: Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D200; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S4, 17.4R3; 18.1 versions prior to 18.1R3-S5; 18.2 versions prior to 18.2R2-S7, 18.2R3; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D50, 18.2X75-D420; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S4, 19.1R2.

Published: July 17, 2020; 3:15:12 PM -0400
V3.1: 6.5 MEDIUM
V2.0: 3.3 LOW
CVE-2020-1632

In a certain condition, receipt of a specific BGP UPDATE message might cause Juniper Networks Junos OS and Junos OS Evolved devices to advertise an invalid BGP UPDATE message to other peers, causing the other peers to terminate the established BGP session, creating a Denial of Service (DoS) condition. For example, Router A sends a specific BGP UPDATE to Router B, causing Router B to send an invalid BGP UPDATE message to Router C, resulting in termination of the BGP session between Router B and Router C. This issue might occur when there is at least a single BGP session established on the device that does not support 4 Byte AS extension (RFC 4893). Repeated receipt of the same BGP UPDATE can result in an extended DoS condition. This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2; 17.2 versions prior to 17.2R1-S9, 17.2R2-S8, 17.2R3-S3; 17.2X75 versions prior to 17.2X75-D105, 17.2X75-D110, 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7; 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2-S6, 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D51, 18.2X75-D60; 18.3 versions prior to 18.3R1-S6, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R3; 18.4 version 18.4R2 and later versions; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect Juniper Networks Junos OS prior to 16.1R1. This issue affects Juniper Networks Junos OS Evolved prior to 19.2R2-EVO.

Published: April 15, 2020; 5:15:35 PM -0400
V3.1: 8.6 HIGH
V2.0: 7.8 HIGH
CVE-2020-1628

Juniper Networks Junos OS uses the 128.0.0.0/2 subnet for internal communications between the RE and PFEs. It was discovered that packets utilizing these IP addresses may egress an EX4300 switch, leaking configuration information such as heartbeats, kernel versions, etc. out to the Internet, leading to an information exposure vulnerability. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D53 on EX4300; 15.1 versions prior to 15.1R7-S6 on EX4300; 15.1X49 versions prior to 15.1X49-D200, 15.1X49-D210 on EX4300; 16.1 versions prior to 16.1R7-S7 on EX4300; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on EX4300; 17.2 versions prior to 17.2R3-S3 on EX4300; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on EX4300; 17.4 versions prior to 17.4R2-S9, 17.4R3 on EX4300; 18.1 versions prior to 18.1R3-S8 on EX4300; 18.2 versions prior to 18.2R3-S2 on EX4300; 18.3 versions prior to 18.3R2-S3, 18.3R3, 18.3R3-S1 on EX4300; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on EX4300; 19.1 versions prior to 19.1R1-S4, 19.1R2 on EX4300; 19.2 versions prior to 19.2R1-S4, 19.2R2 on EX4300; 19.3 versions prior to 19.3R1-S1, 19.3R2 on EX4300.

Published: April 08, 2020; 4:15:14 PM -0400
V3.1: 5.3 MEDIUM
V2.0: 5.0 MEDIUM
CVE-2020-1615

The factory configuration for vMX installations, as shipped, includes default credentials for the root account. Without proper modification of these default credentials by the administrator, an attacker could exploit these credentials and access the vMX instance without authorization. This issue affects Juniper Networks Junos OS: 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on vMX; 17.2 versions prior to 17.2R3-S3 on vMX; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on vMX; 17.4 versions prior to 17.4R2-S9, 17.4R3 on vMX; 18.1 versions prior to 18.1R3-S9 on vMX; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on vMX; 18.2X75 versions prior to 18.2X75-D420, 18.2X75-D60 on vMX; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1 on vMX; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on vMX; 19.1 versions prior to 19.1R1-S4, 19.1R2, 19.1R3 on vMX; 19.2 versions prior to 19.2R1-S3, 19.2R2 on vMX; 19.3 versions prior to 19.3R1-S1, 19.3R2 on vMX.

Published: April 08, 2020; 4:15:13 PM -0400
V3.1: 9.8 CRITICAL
V2.0: 10.0 HIGH