CVE-2017-6627
Detail
Description
A vulnerability in the UDP processing code of Cisco IOS 15.1, 15.2, and 15.4 and IOS XE 3.14 through 3.18 could allow an unauthenticated, remote attacker to cause the input queue of an affected system to hold UDP packets, causing an interface queue wedge and a denial of service (DoS) condition. The vulnerability is due to Cisco IOS Software application changes that create UDP sockets and leave the sockets idle without closing them. An attacker could exploit this vulnerability by sending UDP packets with a destination port of 0 to an affected device. A successful exploit could allow the attacker to cause UDP packets to be held in the input interfaces queue, resulting in a DoS condition. The input interface queue will stop holding UDP packets when it receives 250 packets. Cisco Bug IDs: CSCup10024, CSCva55744, CSCva95506.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.