CVE-2023-0888 Detail

Current Description

An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks


View Analysis Description

Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  7.2 HIGH
Vector:  CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Nist CVSS score does not match with CNA score
CNA:  B. Braun SE
Base Score:  4.9 MEDIUM
Vector:  CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://www.bbraun.com/productsecurity Product 
https://www.bbraunusa.com/productsecurity Product 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-94 Improper Control of Generation of Code ('Code Injection') cwe source acceptance level NIST  
CWE-95 Improper Neutralization of Directives in Dynamically Evaluated Code ('Eval Injection') Reference acceptance level B. Braun SE  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

2 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2023-0888
NVD Published Date:
03/13/2023
NVD Last Modified:
11/06/2023
Source:
B. Braun SE