U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

NOTICE UPDATED - April, 25th 2024

NIST has updated the NVD program announcement page with additional information regarding recent concerns and the temporary delays in enrichment efforts.

CVE-2024-21838 Detail

Description

Improper neutralization of special elements in output (CWE-74) used by the email generation feature of the Command Centre Server could lead to HTML code injection in emails generated by Command Centre. This issue affects: Gallagher Command Centre 9.00 prior to vEL9.00.1774 (MR2), 8.90 prior to vEL8.90.1751 (MR3), 8.80 prior to vEL8.80.1526 (MR4), 8.70 prior to vEL8.70.2526 (MR6),  all version of 8.60 and prior.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  N/A
NVD assessment not yet provided.

Nist CVSS score does not match with CNA score
CNA:  Gallagher Group Ltd.
Base Score:  6.8 MEDIUM
Vector:  CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: NVD Analysts have not published a CVSS score for this CVE at this time. NVD Analysts use publicly available information at the time of analysis to associate CVSS vector strings. A CNA provided score within the CVE List has been displayed.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2024-21838

Weakness Enumeration

CWE-ID CWE Name Source
CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') Reference acceptance level Gallagher Group Ltd.  

Change History

1 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2024-21838
NVD Published Date:
03/04/2024
NVD Last Modified:
03/05/2024
Source:
Gallagher Group Ltd.