CVE-2022-47648
Detail
Modified
This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided.
Current Description
An Improper Access Control vulnerability allows an attacker to access the control panel of the B420 without requiring any sort of authorization or authentication due to the IP based authorization. If an authorized user has accessed a publicly available B420 product using valid credentials, an insider attacker can gain access to the same panel without requiring any sort of authorization. The B420 module was already obsolete at the time this vulnerability was found (The End of Life announcement was made in 2013).
Bosch Security Systems B420 firmware 02.02.0001 employs IP based authorization in its authentication mechanism, allowing attackers to access the device as long as they are on the same network as a legitimate user.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have not published a CVSS score for this CVE at this time. NVD Analysts use publicly available information at the time of analysis to associate CVSS vector strings.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
CVE Source Update by Robert Bosch GmbH11/06/2023 10:56:24 PM
Action
Type
Old Value
New Value
Changed
Source
MITRE
Robert Bosch GmbH
CWE Remap by NIST8/08/2023 10:22:24 AM
Action
Type
Old Value
New Value
Changed
CWE
CWE-863
CWE-290
CVE Modified by MITRE5/04/2023 5:15:09 PM
Action
Type
Old Value
New Value
Added
CVSS V3.1
MITRE AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Changed
Description
** UNSUPPORTED WHEN ASSIGNED ** Bosch Security Systems B420 firmware 02.02.0001 employs IP based authorization in its authentication mechanism, allowing attackers to access the device as long as they are on the same network as a legitimate user.
An Improper Access Control vulnerability allows an attacker to access the control panel of the B420 without requiring any sort of authorization or authentication due to the IP based authorization. If an authorized user has accessed a publicly available B420 product using valid credentials, an insider attacker can gain access to the same panel without requiring any sort of authorization. The B420 module was already obsolete at the time this vulnerability was found (The End of Life announcement wa
Bosch Security Systems B420 firmware 02.02.0001 employs IP based authorization in its authentication mechanism, allowing attackers to access the device as long as they are on the same network as a legitimate user.
** UNSUPPORTED WHEN ASSIGNED ** Bosch Security Systems B420 firmware 02.02.0001 employs IP based authorization in its authentication mechanism, allowing attackers to access the device as long as they are on the same network as a legitimate user.
Initial Analysis by NIST2/16/2023 10:19:17 AM
Action
Type
Old Value
New Value
Added
CPE Configuration
AND
OR
*cpe:2.3:o:bosch:b420_firmware:02.02.0001:*:*:*:*:*:*:*
OR
cpe:2.3:h:bosch:b420:-:*:*:*:*:*:*:*
Added
CVSS V3.1
NIST AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Added
CWE
NIST CWE-863
Changed
Reference Type
https://drive.google.com/drive/folders/16jvVFyp9RlHvXvq7qbOCjCs1jiAPT3i_?usp=sharing No Types Assigned
https://drive.google.com/drive/folders/16jvVFyp9RlHvXvq7qbOCjCs1jiAPT3i_?usp=sharing Third Party Advisory
Changed
Reference Type
https://pastebin.com/raw/0CGTpiEn No Types Assigned
https://pastebin.com/raw/0CGTpiEn Third Party Advisory
Quick Info
CVE Dictionary Entry: CVE-2022-47648 NVD
Published Date: 02/08/2023 NVD
Last Modified: 11/06/2023
Source: Robert Bosch GmbH