National Vulnerability Database

National Vulnerability Database

National Vulnerability
Database

CVE-2016-10395 Detail

Current Description

In FlexNet Publisher versions before Luton SP1 (11.14.1.1) running FlexNet Publisher Licensing Service on Windows platform, a boundary error related to a named pipe within the FlexNet Publisher Licensing Service can be exploited to cause an out-of-bounds memory read access and subsequently execute arbitrary code with SYSTEM privileges.

Source:  MITRE
Description Last Modified:  06/15/2017
View Analysis Description

Impact

CVSS v3.0 Severity and Metrics:

Base Score: 7.8 HIGH
Vector: AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (V3 legend)
Impact Score: 5.9
Exploitability Score: 1.8


Attack Vector (AV): Local
Attack Complexity (AC): Low
Privileges Required (PR): Low
User Interaction (UI): None
Scope (S): Unchanged
Confidentiality (C): High
Integrity (I): High
Availability (A): High

CVSS v2.0 Severity and Metrics:

Base Score: 6.8 MEDIUM
Vector: (AV:L/AC:L/Au:S/C:C/I:C/A:C) (V2 legend)
Impact Subscore: 10.0
Exploitability Subscore: 3.1


Access Vector (AV): Local
Access Complexity (AC): Low
Authentication (AU): Single
Confidentiality (C): Complete
Integrity (I): Complete
Availability (A): Complete
Additional Information:
Allows unauthorized disclosure of information
Allows unauthorized modification
Allows disruption of service

Vendor Statements (disclaimer)

Official Statement from Flexera Software (08/16/2017)

The vulnerability has been analyzed by us as to be exploitable through a locally authenticated user solely in this context. Thus, we assigned the following CVSS metrics and scores for the vulnerability with the CVE identifier CVE-2016-10395:
CVSS version 2: AV:L/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:OF/RC:C
CVSS version 3: AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://ics-cert.us-cert.gov/advisories/ICSA-18-144-01
https://secuniaresearch.flexerasoftware.com/advisories/76368/ Permissions Required Third Party Advisory
https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9134-vulnerabilities-within-schneider-electric-floating-license-manager
https://www.schneider-electric.com/en/download/document/SEVD-2018-046-01/
https://www.schneider-electric.com/en/download/document/SEVD-2018-137-01/
https://www.schneider-electric.com/en/download/document/SEVD-2018-144-01/

Technical Details

Vulnerability Type (View All)

Change History

4 change records found - show changes

Quick Info

CVE Dictionary Entry:
CVE-2016-10395
NVD Published Date:
06/15/2017
NVD Last Modified:
05/29/2018