Description
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY).
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
AND
OR
*cpe:2.3:o:iologik:e1200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.3
OR
cpe:2.3:h:iologik:e1211:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1240:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:moxa:iologik_e1200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.3
OR
cpe:2.3:h:moxa:iologik_e1211:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1240:-:*:*:*:*:*:*:*
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e1200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.4
OR
cpe:2.3:h:iologik:e1210:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1212:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1214:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1241:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1242:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1260:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1262:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:moxa:iologik_e1200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.4
OR
cpe:2.3:h:moxa:iologik_e1210:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1212:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1214:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1241:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1242:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1260:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1262:-:*:*:*:
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e1200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.5
OR
cpe:2.3:h:iologik:e1213:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:moxa:iologik_e1200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.5
OR
cpe:2.3:h:moxa:iologik_e1213:-:*:*:*:*:*:*:*
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e2200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 3.11
OR
cpe:2.3:h:iologik:e2214:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2240:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2242:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2262:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:moxa:iologik_e2200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 3.11
OR
cpe:2.3:h:moxa:iologik_e2214:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2240:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2242:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2262:-:*:*:*:*:*:*:*
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e2200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 3.12
OR
cpe:2.3:h:iologik:e2210:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2260:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:moxa:iologik_e2200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 3.12
OR
cpe:2.3:h:moxa:iologik_e2210:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2260:-:*:*:*:*:*:*:*
Changed
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e2200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 3.13
OR
cpe:2.3:h:iologik:e2212:-:*:*:*:*:*:*:*
AND
OR
*cpe:2.3:o:moxa:iologik_e2200_series_firmware:*:*:*:*:*:*:*:* versions up to (including) 3.13
OR
cpe:2.3:h:moxa:iologik_e2212:-:*:*:*:*:*:*:*
Initial Analysis by NIST3/02/2017 2:13:11 PM
Action
Type
Old Value
New Value
Added
CVSS V3
AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
Added
CVSS V2
(AV:N/AC:M/Au:N/C:P/I:P/A:P)
Added
CWE
CWE-352
Added
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e1200_series_firmware:2.3:*:*:*:*:*:*:* (and previous)
OR
cpe:2.3:h:iologik:e1211:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1240:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e1200_series_firmware:2.4:*:*:*:*:*:*:* (and previous)
OR
cpe:2.3:h:iologik:e1210:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1212:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1214:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1241:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1242:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1260:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e1262:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e1200_series_firmware:2.5:*:*:*:*:*:*:* (and previous)
OR
cpe:2.3:h:iologik:e1213:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e2200_series_firmware:3.11:*:*:*:*:*:*:* (and previous)
OR
cpe:2.3:h:iologik:e2214:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2240:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2242:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2262:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e2200_series_firmware:3.12:*:*:*:*:*:*:* (and previous)
OR
cpe:2.3:h:iologik:e2210:-:*:*:*:*:*:*:*
cpe:2.3:h:iologik:e2260:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:iologik:e2200_series_firmware:3.13:*:*:*:*:*:*:* (and previous)
OR
cpe:2.3:h:iologik:e2212:-:*:*:*:*:*:*:*
Changed
Reference Type
http://www.securityfocus.com/bid/93550 No Types Assigned
http://www.securityfocus.com/bid/93550 Third Party Advisory, VDB Entry
Changed
Reference Type
https://ics-cert.us-cert.gov/advisories/ICSA-16-287-05 No Types Assigned
https://ics-cert.us-cert.gov/advisories/ICSA-16-287-05 Third Party Advisory, US Government Resource