You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
This CVE record is not being prioritized for NVD enrichment efforts due to resource or other concerns.
Description
On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series.
Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
http://www.securitytracker.com/id/1038891 No Types Assigned
http://www.securitytracker.com/id/1038891 Third Party Advisory, VDB Entry
Changed
Reference Type
https://kb.juniper.net/JSA10789 No Types Assigned
https://kb.juniper.net/JSA10789 Vendor Advisory
CVE Modified by Juniper Networks, Inc.7/21/2017 9:29:01 PM
Action
Type
Old Value
New Value
Changed
Description
On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D55 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series.
On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series.
CVE Modified by Juniper Networks, Inc.7/17/2017 9:29:00 PM